Craig and his partner arrived on time and did an excellent job. He also fix my light switch in the master bathroom.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Each and every representative was very professional and courteous.
Overall Experience
Quality
Price
Convenience
Very professional. I will recommend this company and the Tech.
Overall Experience
Quality
Price
Convenience
Very professional crew. They went up and above any expectations. The job was completed on budget and ahead of schedule.
Overall Experience
Quality
Price
Convenience
Great customer service. The technicians were very knowledgeable and very helpful answering any questions that I had. I would highly recommend them.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
For this job, I rendered leak detection services for technician Tahj.
Stair lights not working properly Add outlet at bedroom upstairs, tv outlet, replace 3way switches at stairs and replace switches at bathroom
We arrived back today. We came to fulfilled the estimate of a panel restoration, surge protector, and electrical grounding system. I first removed all of the existing breakers in the electrical panel and replaced them with new ones. Next time installed a search protector on the bottom of the panel. Last and that’s what grounding system was installed in the back of the house. Installed two 8’ ground rods on the backside of the house in front of those ground garage. We ran a number four ground wire all the way to the electrical panel where we installed a ground bar to mount it all. Inside the panel, all of the ground wires were removed from the neutral bar and installed on the new ground bar. I also installed a grounding jumper from the new ground bar over to the neutral bar. Last I separated, all double tapped neutrals on the neutral bar. It was great seeing you again, Karsten! Hope you and your family have a great year. If I can ever help you with anything else, please let me know.
Replacing just the 3 light fixtures no upgrades
I arrived to the property and the customer had a backed up main sewer. I ran a camera inspection to the outdoor clean out. I found a broken section of piping in the yard and an open sewer line with no cleanout cap on top of it in the middle of the yard as well. I discussed with the customer how we would need to do a spot repair on the sewer and then also said how we would put a cap on the random sewer line in the yard. They initially signed off and had to schedule to do the work Wednesday and paid the third deposit then canceled immediately. The estimate will be good for 30 days.
Troubleshoot Estimates for Service and Panel
Troubleshoot for tripping breaker. (See troubleshooting line item for notes) Panel is in desperate need for replacement, besides being 30 years old, it has severely rusted, has been infested by bugs, has no main point of disconnect and no grounding system.
Replaced GFCI in sunroom. Replaced switch for the master bathroom vanity light.
Troubleshoot outlets not working in multiple rooms. Replaced bad outlet. Replaced main breaker in main panel and removed end of one service conductor that was incorrectly installed.
Came out today to perform one system HVAC full inspection. Upon arrival, customer stated that the system was not working and heat mode. Upon inspection of the system, found that the filter was completely clogged, the blower wheel had buildup, the flood protection for the system is not TE standard because it is not a water sensor, Voutdoor condenser coil had build up with leaves and debris, the ductwork is also very dirty, there is no UV protection on the system. Upon replacing the filter and testing the system, found all operations of the system working properly at this time. With the old filter, the system could not breathe, causing the system to go out on high pressure. At this time, customer is reviewing estimates and will reach back out after Christmas.
Performed diagnostic on 16yr old 90% Goodman furnace, upon arrival customer stated unit not heating properly, stated unit is giving code for roll out, upon going in crawlspace can smell a loud egg smell around front door coming from furnace exhaust, inspected furnace, furnace was running due to customer say he reset roll out switch, upon check furnace burners heavily rusted and flame rolling out top burner, inspected heat exchanger epwith inspection camera and found several holes in heat exchanger, showed to customer and explained unit is not safe to run, turn off min power at unit and turned tstst to off mode, recommend install supervisor due to condition of system, customer approved, schedule with office for today, unit not running at time , due to not safe to run