Devon was at our home to install six motion detectors and four outdoor ceiling fans. He called prior to his arrival to let us know when he would be arriving, which we greatly appreciated. When he arrived, Devon was well groomed and very professional. He was very pleasant and personable. It was a very humid day and Devon worked right through it and always had a smile on his face. Devon was very efficient and it was obvious he loved his job! His attention to detail and care of our home was exceptional! We were extremely pleased with Devon and his work and will definitely keep coming back to him for future needs!! As a side note, Devon represented your company with pride in his work and his knowledge. Don’t let him get away!!
Super efficient, knowledgeable and personable. Kept us in the loop the whole way through.
Excellent service. Michael did an amazing job for us today! 10 out of 10! I highly recommend this company.
Wilson & Jasson were friendly, knowledgeable & efficient. Made us comfortable with both the process and and the results.
TE provides exceptional service! We use them for our plumbing and electrical over and over. They are a pleasure to work with. We highly recommend!!!!
Bored 130 feet to replace water line. Tied back in to irrigation and replaced water heater
Use cable to push item out of line and clear blockage
Responded to inadequate cooling for the whole house. Customer stated that prior to our arrival, previous company recharged the system with 410a but the condenser was designed for r22, causing compressor to seize. Company replaced condenser with a 410a system. Started my diagnostic and found several issues. Outdoor board had an error code (11 flashes) indicating W and O terminals are calling at the same time. Found short in thermostat wires. Once wires were fixed system started up, let run for 20-30 min, pressures were not looking good, head pressure was extremely high and the superheat and subcooling were both at 33-35. Upon further inspection found 410a indoor coil had an r22 TXV installed. Recovered refrigerant, pressure checked for any leaks and flushed lines with RX11 before replacing TXV. Replaced with R410 TXV, pressure checked and did a triple evacuation. Added new refrigerant to system started and tested. System is now cooling but the compressor is showing signs that it may
Ran the auger throughout the guest toilet, retrieved a toothbrush. Tested flowing perfectly.
Home inspection and repair rigid mast
Troubleshooting the outside outlet in the garage and basement outside outlet Tripped GFCi in the Garage and Basement Garage -Basement Outside Outlet is damaged None of the Outside Outlets are weather resistant
Installation of new outlets from existing circuitry throughout the home,
Performed 1 system diagnostic found unit taken apart. Universal motor installed with wiring harness cut and wire nutted together. Unit is non operational. Found dirty condenser coil, dirty blower wheel, rusted evap coil, no water safeties, water in pan. Customer opted for the bandaid repair at this time. Will need to install new wire harness and blower to complete further diagnostic. Parts are on order.
Replace 6 small flood lights with new customer provided lights. And replace 3 ceiling fans all outside on porch.
Installed prv and 50 gallon water heater