Overall Experience
Quality
Price
Convenience
The title says it all. We read excellent reviews about TE plumbing and our experience actually exceeded our expectations. Vincent was a great technician and very professional and personable. TE‘s communication was superb. And we found their rates to be very reasonable. If you’re looking for a plumber in the Canton area, we highly recommend TE plumbing.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
James and team did a fantastic job. We will use him and TE to do all our electrical work.
Overall Experience
Quality
Price
Convenience
James provided Excellent service. Really like that he took the time to explain everything to us.
Overall Experience
Quality
Price
Convenience
Tyler is efficient and thorough. He completes the job in a timely manner. The prices are reasonable. Everything was totally cleaned up after the job. I will call Tyler for all my plumbing needs.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Efficient and the work was excellent. Clean up after was immaculate. Price was fair. Will always call on James for all my electrical needs.
Overall Experience
Quality
Price
Convenience
James never fails to deliver 110%. Always above and beyond expectations. I won’t use anybody else.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
James never disappoints! Always thorough and efficient. I can’t say enough great things about the quality of his work!
Overall Experience
Quality
Price
Convenience
The techs did a great job on the water filter installation. They we’re courteous and personable.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Tyler is the best of the best. Always at the top of his craft. Never disappoints.
Overall Experience
Quality
Price
Convenience
Arrived on site and customer stated that the disposal was turning on , but a metal on metal sound was occurring while it ran. Customer asked if I could take it apart and save the unit , which I went ahead and proceeded with. I took apart the disposal and found debri that may have been related to the issue. I also noticed some rust occurring which also could be related to some of the noise as well. I then went ahead and installed the disposal back in place and tested it a few times while running water, which seemed to work. If unit continues to grind , I would recommend replacing as the rust could be breaking down.
The customer had a faulty duel function breaker (6 blinks) that controls the microwave. I supplied and install a new BR 20 duel function breaker for the microwave which is on circuit number 19. I turned the breaker on and tested the microwave I also tested the safety feature of the breaker as well. I informed the homeowner to get in contact with Eaton to send them some newer generation breakers the ones with TL written on the breaker. I have listed below the count and types of breakers needed. Type BR Single Pole 20 AFCI breakers-7 Type BR Single Pole 20 Duel Function-2 Type BR Single Pole 15 AFCI breakers-9
Second floor system : Removed 1 heat 1 cool thermostat and installed 2 heat 1 cool heat pump thermostat. Installed TE Certified flood protection. Installed locking caps. Basement system : Sealed supply plenum with screws and mastic tape. Noticed no collar for 14 inch flex. Installed collar for flex. Main floor system : taped off return pulling air from mechanical room. This was un healthy and could be dangerous.
Service visit on Generac 22kw standby generator
Replace ceiling fan and lights, add new outlet in kitchen
Troubleshoot all outlets and switches not working correctly
Capped off main water line from the city so customers can use their well system. After installation I pressurized the line, checked for leaks. Everything is good. Thank you for choosing te certified
Arrived on site and customer stated the shower handle came off in the master shower. I was able to take the existing shower handle and screw it back in place . It appeared that the screw came loose and needed to be secured again . I tested the handle as well as let the customer test the handle to ensure that the handle was secure .
Troubleshoot on Generac 22kw standby generator
Install new potable water service system to house swapped out prv installed courtesy valve and valve box in the front yard test for leaks no leaks at this time Thanks for choosing te certified
For this job, the customer started the pump in the lift station on the exterior of the house was not working, and causing the high water alarm to go off. After taking a look at issue we noticed that the float had a crack in it, and the pump pit was full of grease. We cleaned out the grease, and also replaced the float in the pit. Once complete we tested our work, and cleaned up.
Arrived on site and met with the homeowners , who stated their Master Bathroom Toilet would run every few minutes. Upon inspection, I provided the customer some options and they agreed on having just the valve replaced, since they just sold the house. I proceeded to replace the flush valve on the existing Kohler toilet only, and after replacements I waiting around to ensure the toilet would no longer run. Toilet is no functioning without issues.
Replaced water stops throughout home. Removed rubber fernco fittings from sewage ejector discharge line and replaced with pressure rated fittings. Reconfigured three sink sink drains: powder bath, basement kitchen and bath. Installed proper p trap configuration with air admittance valves. Replaced whole home pressure regulator and shut off. Pressure is set to 65 psi. Replaced three thermal expansion tanks and installed support brackets. Installed conduit on all three electrical wires going from disconnect to water heater. Swapped hot and cold supply lines for powder lavatory faucet since they were backwards. Removed hair build up from master bathroom lavatory drain and reinstalled pop up that had been taken out Tested all work and everything is working as it should at this time Thank you for choosing TE Certified
Excavate area in front from clean out to street. Create new trench for sewer to street tie in approx 80’. Will install 2 way clean out in place of current clean out and tap clean out where customer ties into sewer. Remove additional PRV closest to the street. Test and cover area back to grade. LIFETIME WORKMANSHIP WARRANTY ON REPAIRS MADE BY TE CERTIFIED Replace sewer line from existing cleanout from house to water meter and ran a new waterline from the water meter to the new sewer cleanout pressure test was good