Timely. Efficient. Used show covers without me having to ask. Explained everything clearly.
Phil showed up when he was scheduled to be here which is always good. He diagnosed the issue and repaired it quickly. Phil genuinely seems to be a good guy.
Dalton came to our home timely to troubleshoot. Dalton definitely knows HVACs, is very professional, and cordial. We really appreciate Dalton for sharing his knowledge, he quickly diagnosed our issues and fixed our upstairs thermostat on the spot. We are now enjoying cool air again upstairs. Dalton gave us a quote to fix the compressor downstairs.
Great prices! The technicians were very nice and respectful of property!
Our experience with TE was excellent from the scheduling process to completion of the work. Our technician Kevin called ahead letting us know when he was going to arrive and was extremely professional. The quality of work was excellent, and TE exceeded our expectations.
Very professional excellent work very clean install on my Tesla charger install. Would you again for any electrical work.
Upon arrival drain line is clogged. Unclogged drain line and replaced p trap and added ss2 switch. Cleared drain line with 2 gallons of water. Recommend doing this to both systems as the other system has no flood protection either. Would also recommend replacing both drain lines completely. System is now draining properly with a drain line switch.
Perform camera inspection through clean out. Located a pvc pipe separation which has roots growing into it. Will need to dig down and make proper repairs. Also bring in fresh dirt to Repwlce sewage filled mud from long term sewage leak.
Came out for no hot water in master gave estimate customer agreed pulled old cartridge out replaced with new cartridge tested no failure. Customer asked if we could look at toilet install hall for a leak found stop leaking gave estimate customer agreed cut out old stop installed new stop and supply line also replaced fill as a courtesy. Tested no failure at this time
Came out for leak gave estimate customer agreed installed new expansion tank , temperature and pressure relief valve,pressure regulator valve tested no failure at this time
Came out today to install new condenser fan motor for the upstairs unit, replace the outdoor capacitor for the upstairs unit, and fixed frayed wires on both outdoor units. Upon starting the upstairs system back up clear drain line with mighty pump and insured proper drainage. The homeowner is aware they have no flood protection on the system and its system floods and causes ceiling damage. Customer is responsible for all damages. Also, there is no warranty besides the motor we replaced on the system. At this time system is cooling properly.
Came out today to to perform upstairs system no cool service call. Upon arrival, customer stated that the fan on the outside system is not spinning. Upon inspection of the outdoor system found bad capacitor on the Herm side, the condenser coil is dirty, the wires for low-voltage are exposed copper on both units, the condenser fan motor is bad. Inspection of the indoor system found bad indoor blower capacitor, the blower wheel is dirty, the indoor coil has rust on coil, there is no flood protection. Customer wants to schedule install supervisor and is speaking with her home warranty company to see how she wants to move forward. At this time, the upstairs system is not currently working, and I left disconnect and the off position, so no further damages are made. Customer is aware if repairs are made that this could be an ongoing issue and more issues will appear.
Replace Flood light and Reroute wire for laundry room
Client has us out today because their 1/2 hp garbage disposal is leaking from the bottom, the unit is still operating surprisingly. I presented options and today we went with installing our 1/2 hp badger, work is dome and client is happy with work performed.
The bare minimum basic repairs to get the system running today.
Arrived to install new txv, pumped down refrigerant into compressor, removed failed txv, installed new txv, brazed with nitrogen, checked for leaks, pulled vacuum, released refrigerant also added 4lbs r410a, checked pressures, temp split, unit working properly at time
Performed diagnostic on 6yr old carrier unit for main floor, upon arrival customer stated unit wasn’t cooling properly, checked both tstats, cycled to ac mode, unit started up, went in attic and inspected furnace, checked filter, blower , blower capacitor, airflow, checked both zones, recommended TE flood protection such as wet switch to help prevent water damage, customer approved , install new wet switch, inspected outdoor unit , found condenser coil impacted, recommend cleaning condenser coil, customer approved, chemical cleaned condenser coil, checked capacitor, found failed on condenser fan side reading 1, checked amp draw on condenser fan motor, found over amping , recommended replacing condenser fan motor and capacitor, customer approved, went to pick up parts, returned and installed new condenser fan motor and new capacitor, started unit up and rechecked pressures and temp split, after letting unit run system is showing signs of failing txv, recommended replacing txv for unit t
Based on our findings today, it might be time to think about getting a brand new system. System not cooling properly. Found filter very dirty and low on r22. And has a restriction. System struggles to keep cool in the heat of the day rising over 10 degrees. Duct work has multiple air leaks, and is over 30 yrs old. Lacking lots of insulation. Contactor is pitted and cap is poor. System does not have any warranty to it. Do not recommend repairs due to cost and warranty purposes. Coil is dirty as well