The customer called out TE Certified plumbing 4/25/2025 due to Atlanta Gas Light performing a gas leak search on the customers gas line and was able to find a leak outdoors where the black iron pipe goes under ground. 4/28/2025 I arrived to the customers home and performed the gas line replacement coring a new penetration into the crawl space and running approximately 30 feet of gas line. I tied back in the main line where it branches off to feed individual appliances. I performed three separate gas tests at 15 psi, for 15 mins to ensure no gas leaks. All of the approved gas work has been completed and tested for leaks. A concern about the customer’s venting and open “box” on their vent line was addressed and there’s a risk of carbon monoxide but the customer declined any services. Also the customer was informed that TE Certified would not light the customer’s 1922 furnace due to the potential harm that may be caused relighting it. The customer understood and declined a professional