Today we performed a due diligence buying inspection as well as a home inspector report inspection. I included three estimates one with priority task to be completed, one with the remaining task that need to be completed, and lastly, an estimate for updating the service to the home. This estimate is if we are able to flip the panel around into the bedroom, but it will be up to the inspector if we can do that. The home has an older SEU service running to 125 amp breaker in the main panel. The main panel is square D home line brand with twin breakers throughout the panel. If you ever wanted to update all of your circuits to dual function, AFCI/GFCI breakers you would need to change out the panel so that it has more space. The panel is located in the stairwell, but could be flipped around into the bedroom on the opposite wall. Most of the wires in the home have been replaced and updated to romex with grounds. Smoke detectors are updated per code as an addition was added onto the home. E