Joel C.

Joel C.


Job Checkin

Troubleshoot electrical issue. ISSUE: breakers tripped in both bedrooms a couple times LOCATION: master bedroom and bedroom on the other side of home FINDINGS: breakers were on when we arrived, we checked light switches and outlets, and then installed a brand new dual function breaker to test the circuits. RESOLUTION: it is possible that the arc fault breakers are failing due to being old/1st generation. Our solution is to change them out to the current generation dual function breakers, ensuring safety. If they trip again, it will be because something is wrong on the circuit and we need to come back and troubleshoot at $149 or something was plugged in that caused it to trip. With the new breakers being installed on the circuit it tells me that both circuits are at the safety standard of dual function arc fault/GFCI breakers. While on site, we changed out smoke detectors that were original to the home five in total. We are leaving a quote for surge protection and a quote to retrofit