Antonio T.

Antonio T.


Job Checkin

Upon arrival customer stated that ac unit had stopped working as of yesterday. After inspection of system found that unit had a drain pan full of water that activated the pan float switch and turned system off. There was a clogged (16x20x1) system filter and qty 2 (14x14x1) clogged filters in the return vents inside home. The system froze due to no air flow. Checked over system by by passing the float switch to ensure unit turned on and everything came on. Blower capacitor is testing bad. The disconnect was by passed and load is hooked into the voltage coming from panel, wires do need to be separated and new disconnect installed. Checked outdoor unit capacitor and contactor tested good with no issues, condenser coils are very dirty. Gave customer estimate to remove water from drain pan, replace bad blower capacitor, clean outdoor condenser coils, add in line float switch and wet pan switch. Customer declined all recommendations at this time. Customer stated that they will clean water f