Customer called us out for a clogged kitchen sink. On inspection I found that the most likely cause was grease and cast iron. I recommended running a tub gun because there was galvanized steel piping and I did not trust the k-400 to not break it. Customer agreed. I removed the ptrap and ran the tub gun down the line clearing the blockage. I then assembled the ptrap and tested it for 15 minutes. There were no leaks in the crawlspace or under the sink. Customer is not interested in having a sewer supervisor out.
Installed customer supplied double vanity, lavatory faucets, tubular sink drains and hot/cold water lines for sinks in master bathroom. Tested and inspected. Working properly and no leaks.
Came out for multiple issues gave estimates customer agreed to replace hall toilet and cartridge in master tested no failure at this time.
Replace DC transform with AC transformer at the main intercom point in the kitchen, traced out the Low Voltage wires going down to the main entrance NuTone intercom talk box, moved low voltage wires and 120v wires into new junction box with transformer. Installed new customer supplied ring camera at main entrance with a customer plate covering old NuTone Box.