Came out due to the ceiling falling from water damage. Upon inspection of the system found that the drain line was clogged up, and very slow to drain. Also found that this is heil air handler in attic and the extra PVC drain ports from the coil. We’re not capped off, allowing free flow once the water reached that level of the drain pan. Also performed a fully evaluation over the equipment found that the indoor coil was very rusty, the indoor blower motor had a large amount to build up, also found biological growth throughout the entire system in the attic. Upon inspection of the outdoor system found the condenser coil is dirty, the outdoor capacitor was bad and out of range from what factory says, also throughout testing the system found it as low on 410 a refrigerant. Due to the buildup on the system cannot get an accurate reading of refrigerant one system is cleaned. It would indicate the system is also lower on charge than what it is reading now. Upon speaking with the homeowner he