Job Checkin

SERVICE CALL: upon arrival homeowner stated the outdoor condenser unit stop working. After complete troubleshooting I found the package unit 3 1/2 ton capacity 6 years old is in Poor maintenance conditions the Condenser fan motor is overheating and running on high amperage and Open internal overload and stop working motor was replaced 2 years ago And the Dual run capacitor 45/7.5 is not the correct one for this unit Needs 45/5.0 uf this system is 6 years old and is out of warranty. I recommend new oem condenser fan motor new oem Dual run capacitor And Condenser coil cleaning with chemical to restore efficiency. Homeowner is aware of the conditions of the system. Parts are not available and we need to order will take 2 to 3 business days to get parts. Homeowner approved repairs and we will order parts asap to return to complete repairs. Thanks for choosing TE CERTIFIED. Homeowner sign up for HOMECARE PLAN.