Job Checkin

Upon arrival customer stated that system was not working correctly and was shutting on and off. Stated that system was doing this same thing last year she had it fixed and now this year it started doing g the same thing. After inspection of system found that unit has a failing gas valve. Along with gas valve control board was dropping voltage. Blower wheel is very impacted, blower motor capacitor is bad, system has gas flex line entering the cabinet. Gas furnace is 32 years old, ac and coil is 8 years old. Gave customer estimates for repairs, advised customer that these repair options are band aid for system and inducer draft motor and heat exchanger can still fail at anytime due to the condition of the furnace and age. Repairs recommendations were new gas valve, control board, blower wheel, blower motor and blower motor capacitor. Customer declined recommendations at this time. Recommended speaking with our install supervisor about updating aged equipment, customer does want to receiv