Brandon R.

Brandon R.


Job Checkin

We arrived back here today, October 13 to fulfill the work on the estimate. We installed six direct wire ballast bypass 4 foot T8 bulbs on three separate lights. We removed the existing ballast on all three lights, and once everything was finished all three lights worked properly again. Last we ran a new circuit from the electrical panel in the basement across the basement ceiling about 60ft, where we drilled a hole up into the wall to gain access to Mr. Weston’s bedroom where we installed a plastic cut in box, white duplex receptacle and cover. Installed a 20 amp Siemens dual function breaker in the panel to control power for the new circuit. Made all wire connections and the new circuit worked properly. It was very nice meeting all of you! If we can ever help you with anything else, please let us know. Thank you, Brandon