For this job, I installed a new outlet on an existing lighting circuit in the living room of the finished basement. The scope of work included cutting in a new box below the existing light-switch box, fishing a new cable down to the outlet location, installing the new receptacle and cover plate, and tying the new wiring into the existing circuit at the switch box. During the visit, the customer also requested that I investigate intermittent light flickering occurring in multiple rooms. I performed a courtesy inspection that included checking for voltage fluctuations (none observed), verifying torque on terminal screws in the main panel and branch circuits, and inspecting the main breaker connections with a focus on neutrals. Because the issue affects multiple areas of the home, it is likely related to a utility-side problem or potentially an aging main breaker. I also completed a load calculation to confirm the home was not exceeding its available amperage capacity. Based on the findin