9800 Old Dogwood Rd.
Roswell, GA 30075
(770) 667-6937

Our Top Cities


Job Locations
for acworth, ga


Map of Acworth GA
James D.

James D.


Job Checkin

Today we completed the following work in the den/ living room and at the panel. *In the living room off the den remove the single gang box and supply and install a new 2g box. *Wire in a new 14/3 switch leg from the box to the center of the dens high ceiling *Install a fan rated pancake box *On other wall in den remove the single gang box (dead end 3way) and supply and install a new 2g switch box. *Supply and install a Lutron Smart switch switch a wireless switch and bracket. *Supply and install new plates for each box. Possible dry wall cutting may occur due to framing or blocking. Install a Lifetime warranty surge protector inside the main panel Install tandems to create space in main panel for the surge. Remove the illegal tandem breaker inside the panel and supply and install a manufacturer approved type. We was not able to sync the Caseta switch today due to the fixture not being installed. I left the instructions on the kitchen island per homeowners request. I also i