Torrel W.

Torrel W.


Job Checkin

No heat. Upon arrival found heat pump running fine, issue was with emergency heat not kicking on when temperature got below 35 degrees. Found broken thermostat wire (W) after checking electrical connections and checking wire resistance. Advised customer we would have to get electrical out to run new wire in order to make repair, customer requested we just change thermostat settings and allow heat pump to run under 35 degrees and they will just use heat pump only.