Upon arrival customer stated that she was smelling a burning smell of wires coming through supply vents. After inspection of system found that unit had a failed blower motor capacitor. Recommended replacing the blower capacitor to further inspect the system, customer approved to do so. Replaced capacitor and system came back on, blower motor is pulling high amps due to running under a weak load for a while. Advised customer that blower motor can still eventually end up failing recommended changing customer declined recommendations at this time. As used customer of flex gas line going into cabinet recommended bringing gas line up to code with hard iron pipe customer declined recommendations at this time. Inducer draft motor is over amping due to age of system. Recommended speaking with an install supervisor about updating aged furnace. Customer declined recommendations at this time. Checked outdoor unit heat pump is 4 years old, capacitor and contactor tested good with no issue,condense