Job Checkin

Inspection for a homeowner that is selling his house. House has three 23 year old r22 systems, one in the basement and two in the attic. Basement unit is a heat pump with a dirty blower wheel, biological growth on the evap coil, failed dual and run capacitors, and the condenser is not running. The main floor unit has an r22 condenser and a 410a evap coil, a dirty blower wheel, biological growth in the system, failed dual capacitor, high amp readings for the compressor a dirty condenser coil, and it does not have te standard flood protection. The second floor unit has a failed run capacitor, a dirty blower wheel, biological growth in the system, high amp readings for the condenser fan, a dirty condenser coil and it does not have te standard flood protection. Based on our findings today, it might be time to think about getting a brand new system.