Tech was out today for no cooling . Checked all safety’s and components . The list of the following is needing to be replaced for system to function properly. Blower motor is needing to be replaced due to oil leaking out of motor , this indicates that the bearing in the motor is going bad. Damper motor to master bedroom is making clicking noise and struggling to open damper. This indicates a damper motor failure. Drain line is needing to be cleared to properly insure drain line is clear and no clogs . On condenser capacitor has completely failed 45/7.5 causing the system to to to operate. Condenser is needing to be chemically cleaned. Spoke with customer about repairs that are needed to be done customer only wanted capacitor replaced at this time. Let customer know that the others issues are needing attention quickly before other parts start to become faulty due the issue that have been addressed.