Was called out to this home today due to no heat. Upon inspection first thing I noticed was the inducer motor is completely gone. Upon further inspection found that the burners are very rusty and need to be replaced. Also found the blower motor very dirty if I clean the blower motor, it will cause the blower to fail. The reason for filling is you relieve all the stress and the motor doesn’t know how to handle it. Upon further inspection also found a crack in the heat exchanger. Also on the blower motor, the capacitor is weak and out of range. Upon inspection of the outdoor unit found debris on the inside and coils very dirty. After bringing all these issues to the homeowners attention, he would like to proceed and have an install manager come out and give him quotes on updating his system. System is shut down right now due to safety concern of electrical from the inducer motor being gone.