Rebuild master bathroom toilet, replace shut off valve for same toilet,replace emergency shut off in crawlspace, replace prv in crawlspace, replace expansion tank in crawlspace. Customer agreed to this option. Replace the emergency shut off valve in the crawl space with a quarter, turn ball valve as well as installed A25A. U. B prv. Also replaced full and failed thermal expansion tank above the water heater and bracketed. Get to the water heater. I then went to the master bathroom toilet and replaced the stop valve and replaced supply line, fill valve and flapper for the toilet. As well as tank to bowl bolts. He turned water back onto the house and tested work. No leaks and up the toilet is flushing. With all stop valves working. pressure is set to 50 psi. Thank you for choosing and trusting t e with your plumbing needs