ONE SYSTEM HOME INSPECTION: Check media filter Honeywell 16x25x4 is Highly impacted this can create airflow restrictions check indoor blower wheel is highly impacted this can damage variable speed blower motor Flushed drain line with one gallon of water test condensate pump is working at this moment test heat mode is working check gas furnace unit trane 3 ton drive 18 years old recommend DUCTCLEANING plus install new whole House uf light system this will improve indoor air Quality. Test outdoor Heat pump unit Trane 3 ton capacity 18 years old R 22 refrigerant type Which is already phased out by EPA test variable speed condenser fan motor test Dual run capacitor ok check contactor is pitted and start making Noise that’s indication of possible failure check condenser coil is highly impacted and increased the head pressure recommend new contactor complete condenser chemical cleaning to restore efficiency check refrigerant charge pressures are not accurate due to dirty filter dir