2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for shelby township, mi

Rated 5.0 out of 5 stars based on 6 customer reviews

Excellent Service!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Fast/ excellent service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service

Very polite & friendly. Communication was good!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

George Smith Excellent Pro

George is a pro!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Awesome professional service

Fire pros always does a thorough job

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

great service

great professional and friendly

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Job Locations
for shelby township, mi

Mark S.

Mark S. Job Checkin


Sean W.

Sean W. Job Checkin


Robert G.

Robert G. Job Checkin


Robert G.

Robert G. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Emergency Service Call There is a lo-air supervisory on the panel. It seems they have a leak in the dry system. This has been an issue in the past. Site is requesting emergency service for today. Repair of Low air supervisory dry system has leak 3rd floor pump rm pumped system back to normal pressure and cleared panel


Terrence  J.

Terrence J. Job Checkin


Terrence  J.

Terrence J. Job Checkin

2/21/24 Sent email regarding DH Sprinkler Inspection Annual sprinkler inspection Deficiency: Sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: Sprinkler system is due for five year internal obstruction investigation of piping. 2- victaulic couplings Deficiency: Number one control valve needs sign. 1- control valve sign Deficiency: There is no evidence of five year sprinkler system fire department, connection, Hydro test. Deficiency: Sprinkler system is due for five year internal inspection, Fire department connection check valve. 2- 4” victaulic couplings


Terrence  J.

Terrence J. Job Checkin

2/21/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: Missing, concealed head wrench, in head box for a tyco 3531 Deficiency: Fire sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: The sprinkler system is due for five year internal inspection, fire department, connection, check valve. 2- victaulic couplings Deficiency: Sprinkler system is due for five year internal obstruction investigation of piping. 2- 4” victaulic couplings Deficiency: One control valve sign for lower control valves needed. 1- control valve sign Deficiency: Fire sprinkler system is due for five-year Hydro test. Deficiency: Missing, concealed head wrench, in head box for a tyco 3531


Mark S.

Mark S. Job Checkin


James J.

James J. Job Checkin


Mark S.

Mark S. Job Checkin


David H.

David H. Job Checkin


Mark S.

Mark S. Job Checkin


Alex H.

Alex H. Job Checkin


Mark S.

Mark S. Job Checkin