So I was wondering if Corey was unique in this company; by that I mean his personality, dedication and efficiency. Today I found out that he is not, which is an awesome thing. Zach is terrific too! So I am encouraged that Fire Pros seeks out the type of employee that makes them a reliable, efficient, sought after partner. I appreciate the staff and service. Thank yo Zach for a job well done!
Thank you for sending Corey! Our location can be a challenge to negotiate and he was great with it. It felt like we were a team right from the start. Truly appreciate the prompt service.
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
We appreciate your feedback Cyndi and review.
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
Thank you for leaving your review! We greatly appreciate your feedback and are glad that we provided you valuable service! At your convenience, please consider sharing your experience on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day!
Gary was easy to work with. He was polite, knowledgeable and completed his job quickly and professional. I would recommend to anyone who needs that service! Its nice to see another company that knows how to treat its customers.
- During the annual inspection of the fire extinguishers it was determined (8) are due for additional work and need to install a K-Class new as required per NFPA standards (8) 10# ABC HYDRO TEST (1) NEW 6-LITRE CLASS K INSTALLED W/ SIGNAGE _______________________________________________________________________________________________________________________________________ NFPA CODE (Fire Code) Section 5.5.5.3 When a wet chemical fire suppression system is present over cooking equipment, a K-Class extinguisher is still required as supplemental protection. Section 6.1.3.8 The maximum travel distance to a K-Class extinguisher shall not exceed 30 feet (9.15 meters) from the hazard. _______________________________________________________________________________________________________________________________________ Portable Extinguishers Repair
Deficiency: Several Portable Fire Extinguishers are due for service. No Class K in kitchen. Inoperable Deficiency: FIRE ALARM DID NOT ACTIVATE WHEN SYSYEM ACTIVATED. HOOD DISPLAY DID GO INTO FIRE MODE, BUT NOT FACP. ALL WIRING CONNECTIONS ARE MADE IN CABINET. NEED TO BE MADE IN OUTSIDE JUNCTION BOX. TRUCK SERVICE FEE (1): ANNUAL FIRE EXTINGUISHER INSPECTION (9) ANNUAL EMERGENCY LIGHTING INSPECTION - 90MIN (15) SEMI ANNUAL KITCHEN SUPPRESSION SYSTEM INSPECTION (1) 3 GAL SYSTEM - NO DETAILS ABOUT SYSTEM Portable Extinguishers, Emergency / Exit Lights, and Kitchen Suppression Inspection
Annual Exit & Emergency Lighting Inspection (19 units) **MUST COORDINATE WITH SPRINKLER Annual Fire Extinguisher Inspection (3 FE) **MUST COORDINATE WITH SPRINKLER Emergency / Exit Lights and Portable Extinguishers Inspection
Alarm Inspection (1) DMP fire alarm panel with (1) smoke detector above panel. Installed and Monitored by TKS Security
customer changed battery on smoke but still chirping , it is in the treatment area .See Jill Smith
Fire Alarm Inspection DMP- 11 smoke detectors
Annual Fire Alarm Inspection (29 devices) (First Alert FA 1600-C)
Annual Fire Extinguisher Inspection - 14 Fire Extinguishers Portable Extinguishers Inspection
Sprinkler, Obstruction Investigation, and Hydrostatic Testing Repair