Kitchen Suppression and Portable Extinguishers Inspection


Jim S.

Jim S. Job Checkin

10/16 - Scheduled with Chris  mh Kitchen Suppression Inspection Semiannual Kitchen Inspection FireSoft Due Date: 4/10/2019


Alex R.

Alex R. Job Checkin

Completed Annual Fire Extinguisher inspection for 2020


Alex R.

Alex R. Job Checkin

Completed Annual Smoke Alarm inspection for 2020


Alex R.

Alex R. Job Checkin

Completed Annual Smoke Alarm inspection for 2020


Alex R.

Alex R. Job Checkin

Completed Annual Smoke Alarm inspection for 2020


Robert W.

Robert W. Job Checkin


Alex R.

Alex R. Job Checkin

Completed Annual Fire Alarm inspection for 2020


Robert G.

Robert G. Job Checkin


George S.

George S. Job Checkin


Alex R.

Alex R. Job Checkin

Dropped off 2-10 lb RECHARGED CO2 Extinguishers, and Inspected 12 New Customer Supplied 10 lb CO2 Extinguishers and Updated Inspection Report


Alex R.

Alex R. Job Checkin

Dropped off loaners


Alex R.

Alex R. Job Checkin


Alex R.

Alex R. Job Checkin

Emergency Service Call Follow-up


Alex R.

Alex R. Job Checkin

Arrived On-Site FACP was in trouble and showing supervisory. The Audio EVAC Message was playing over the speakers and would not reset. Also the FACP stated NAC 1 and 2 Short. The supervisory was (North Stairwell Tamper ) found Tamper switch required adjustment. Adjusted and reset point, then FACP stated 3rd floor trash Room photo smoke was wrong type of device. replaced smoke head and reset device. The FACP is still stating Local Network 1 and 2 Node 1 and 2 and 3 Troubles the FCI GAMEWELL VOICE EVAC PANEL IS NOT COMMUNICATING WITH FACP. After further Trouble shooting, we have diagnosed problem to being voice evac network card failure and will check shop in AM to see if we have a part for replacement. We have tested the system. alarms still activate at FACP and visuals still function but Audio does not. We also have checked and made sure that the panel is communicating with guardian alarm which it is. Service will Return in AM or contact site maintenance if we have part for replacemen