2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for battle creek, mi

Rated 4.8 out of 5 stars based on 38 customer reviews

Tyler was AMAZING

Not only did he complete the work and do it well BUT, he helped us with one of our residents and never batted an eye. Great guy!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Nice and professional

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service Tyler. is nice and friendly

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service!

As always I got fast response and the appointment was made for the next day. Mike handled the problem I had and the system fully operational.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

got the job done, thank you

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Awesome service!

Awesome service from Mike! He was very very helpful, patient and friendly, he wanted to make sure I am fully understood the system and how to use it! I am left satisfied with ability to feel comfortable with handling the system on my own. Thank you!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

very nice staff

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

very nice staff

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

very nice staff

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Maintenance

I think it was a bit of a challenge as the water did not want to shut off but Russ got it to work

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Job Locations
for battle creek, mi

Art L.

Art L. Job Checkin

Portable Extinguishers Inspection


Russ F.

Russ F. Job Checkin

Sprinkler Inspection


George S.

George S. Job Checkin


Mike R.

Mike R. Job Checkin

Katie called in- phone company shut off phones- system now not testing- phone co "fixed" them-alarm is still going off- needs someone out to check them. CMS ACCT# FLV66396


Christian L.

Christian L. Job Checkin


Tyler H.

Tyler H. Job Checkin

Bi-annual Sensitivity Testing (34) devices Annual Fire Alarm Inspection (62 devices) FireAlarm - Potter PFC6075


Christian L.

Christian L. Job Checkin


Tyler H.

Tyler H. Job Checkin

Bi-annual sensitivity testing - (35) devices Annual Fire Alarm Inspection (64 devices) (Potter PFC 6075)


Tyler H.

Tyler H. Job Checkin

Katie - system trouble NAC Module trouble and power failure 269-615-0519


David H.

David H. Job Checkin


David H.

David H. Job Checkin


Tyler H.

Tyler H. Job Checkin

Annual Fire Alarm Inspection (89 Devices) (Pyrotronics system 3 CP31)


David H.

David H. Job Checkin


Mike R.

Mike R. Job Checkin

door # 23 tripped. Service to add spacer to door . Office would like to have her pay for service at time of service.


Tyler H.

Tyler H. Job Checkin

MP 7TH FLOOR EAST: System is showing a trouble on the 7th floor east. Wire is solid all the way to the end of the circuit at the manual pull on the 7th floor. Removed all devices from the zone and it still shows trouble. Wire is reading about 4.5-30 k ohms. Zones have end of line capacitor instead of end of line resistor. Need to return with 2 guys to locate where wiring goes to the 7th floor and possible pull a new one. This wire will need to run from FACP to 7th floor smoke detector, unless we locate a problem with the wiring somewhere along the way. - repair This quote is for two alarm technicians to have the time to trouble shoot the reason why there is a 7th floor trouble on the panel