12/26/23 Sent email regarding inspection DH 12/12/23MV Emailed Jim regarding inspection date 12/13, waiting on confirmation Sprinkler Inspection Annual Fire Sprinkler Inspections (1 Wet & 1 Dry System) 5-year Internal Due: FDC Hydro Due: Full Flood Due: 2023 Deficiency: Which system is missing control valve sign. Deficiency: There is no evidence of five-year internal inspection, fire department connection, check valve 2- victaulic couplings Deficiency: There is no evidence of five-year internal inspection, dry sprinkler system valve 2- victaulic couplings Deficiency: Sprinkler head box needs a universal wrench. 1- universal wrench Deficiency: Wet sprinkler system needs drain and test sign. 1- metal test and drain sign Deficiency: There is no evidence of five-year internal obstruction investigation, wet sprinkler system. 2- victaulic couplings Deficiency: Sprinkler system is due for gauge change dry sprinkler system. 2- sprinkler gauges Deficiency: There is no evidence of f
11/20/23 Sent email regarding inspection DH / Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Tech will need to bring (2) water gauges on 2023 inspection 5-Year Internal Due: 2023 FDC Hydro Due: 2023 Deficiency for Wet Training room closet: Outdated water gauges x2 Deficiency: Return trip required to pipe out ITV. Lift required Hilo to short 1- 1” ball valve 2- 1” galv wall plates 2- 1” 90 1- 1”x 3/4”galv 45 2- 3/8” drop in anchors 2- 1” cls ptrn ring 1-3/8” TBC 3/8” ATR 1- 1” loop ring 1x 3/4” 155 brass upright for head box 1- ITV sign w/chain 42’-0” 1” Deficiency: Inspectors test valve on side of building up front is intact and just needs a sprinkler head to reduce it 1- 1/2” brass, 155° sprinkler head half-inch orifice. Deficiency: Sprinkler system fire department connection check valve is due for internal inspection of valve Deficiency: Sprinkler system is due for five year internal pipe investigation for obstructions. 1- 4” victaulic coupling Deficiency:
10/26/23 Confirmed with Harden R. for 10/31/23 at 8:00am. DH PO IS REQUIRED NOTE #1: The SP risers in outside mechanical rooms are located in; Bldgs. #1-4, #2-3, #5-6, #7-8, #9-10, #11 & #12. ***** There are (7) Risers total.** Sprinkler and Backflow Inspection Annual Fire Sprinkler System Inspection Annual Back Flow System Inspection/Test Deficiency: Building, Twelve, Sprinkler,needs gauge change. 1- water 💦 gauge Deficiency: Building Twelve is due for five-year internal obstruction investigation. 2- 2” Victaulic couplings Deficiency: Building Twelve is due for five year fire department, check valve internal inspection as well as Hydro test 2- Victaulic couplings 2” Deficiency: Building 11 Sprinkler system is due for internal obstruction investigation 2- 2” Victaulic couplings Deficiency: Building 11 is due for gauge change 1- water 💦 gauge Deficiency: Building 11 is due for fire department connection, check valve internal inspection. 2- Victaulic couplings 2” Deficiency: B