2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for rochester hills, mi

Rated 4.9 out of 5 stars based on 17 customer reviews

Excellent Service!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

George did great

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

General manager

Very punctual and let’s you know what he is doing from beginning to end

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great fire system service

Great service experience, serviced suppression system and made sure all cables and links were cleared and properly functioning. Outstanding job.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great team work!

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Building / Facilities Manager

Both George and Tony were professional and exceptional in their work and skills sets. Appreciated having them not only service our site but offer some advise and educate my myself with their knowledge and expertise.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Maintenance Supervisor

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Store manager

Great service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Executive Director

Pleasant nature, explained everything - pleased with the service rendered.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Owner

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Friendly and Knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Customer service lines

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rochester hills, mi

Terrence  J.

Terrence J. Job Checkin

2/16/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)


Terrence  J.

Terrence J. Job Checkin

3/13/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Inoperable Deficiency: The sprinkler system is due for a five-year Hydro test fire department connection 1- 4” victaulic coupling Deficiency: The fire sprinkler system is due due for five-year internal obstruction investigation of piping. 1- 4”x 2.5” coupling Deficiency: Fire sprinkler system is due for internal inspection of fire department connection check valve. 2- 4” victaulic couplings


James J.

James J. Job Checkin


Terrence  J.

Terrence J. Job Checkin

2/21/24 Confirmed by Chris for 2/26/24 at 8:00am DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspections (4) Wet (1) Dry Deficiency: Leak on 1” pipe and union in electrical room over by maintenance garage. Will need: 10’ of 1” pipe. (1) 1” union. Deficiency: Sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: Sprinkler system is due for five year internal obstruction investigation piping. 2- 4” victaulic couplings Deficiency: Sprinkler system is due for internal inspection five year fire department connection check valve. 2- 4” victaulic couplings Deficiency: Sprinkler system is due for five-year Hydro test of fire department connection Deficiency: System number two is due for five year internal obstruction investigation. 2- 4” victaulic couplings Deficiency: System number two is due for gauge change. 1- sprinkler gauge Deficiency: Dry pendant heads in cooler and freezer of administration building are to be removed an


Mark S.

Mark S. Job Checkin


George S.

George S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Inspection 1/11/24(TJV)- Mike G confirmed for 1//17 **Customer would like all inspections coordinated at the same time... fire alarm also needs to be coordinated with the customer's elevator company (customer reaches out to elevator company then will let us know when he is good to schedule the other inspections) [KR] Ann Wet Sprink Deficiency: Sprinkler system is due for internal obstruction investigation. 1- 4” victaulic coupling Deficiency: Sprinkler system. Fire department connection is due for Hydro test. It is a Stortz connection. Deficiency: Sprinkler system fire department connection check valve is due for five year internal inspection. 2- 4” victaulic couplings


Terrence  J.

Terrence J. Job Checkin

1/4/24 Confirmed with Monica for 1/8/24 at 8:00 DH 12/26/23 Tentative date for 1/4/23 DH 12/19/23MV Emailed Monica with new inspection date. They are close until January 2nd 12/11/23MV Emailed Monica regarding inspection date 12/14, Monica would like a different date. Sprinkler Inspection Annual Sprinkler Inspection (1 Wet Sprinkler System) Deficiency: There is no evidence of five-year internal inspection of fire department connection check valve and fire department connection piping Hydro testing. The fire department connection check valve is pinned behind a garage door track this check valve cannot be inspected or removed unless door track is moved to accommodate getting in that space please make note the customer should be made aware of this condition Deficiency: System is due for five-year internal check valve inspection for fire department connection but the rollup door at the back of the building is obstructing the check valve and if roller is not removed valve cannot be accesse


George S.

George S. Job Checkin


Mark S.

Mark S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

11/22/23 Confirmed with Kari FAS for 12/13/23 at 8:30. DH Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: Quick response heads are due for testing 4- 155° brass upright quick response 1/2”


George S.

George S. Job Checkin


George S.

George S. Job Checkin


Mark S.

Mark S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Warranty Call Replace coupling above new monitored valve.