Very punctual and let’s you know what he is doing from beginning to end
Great service experience, serviced suppression system and made sure all cables and links were cleared and properly functioning. Outstanding job.
Both George and Tony were professional and exceptional in their work and skills sets. Appreciated having them not only service our site but offer some advise and educate my myself with their knowledge and expertise.
Pleasant nature, explained everything - pleased with the service rendered.
2/16/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)
3/13/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Inoperable Deficiency: The sprinkler system is due for a five-year Hydro test fire department connection 1- 4” victaulic coupling Deficiency: The fire sprinkler system is due due for five-year internal obstruction investigation of piping. 1- 4”x 2.5” coupling Deficiency: Fire sprinkler system is due for internal inspection of fire department connection check valve. 2- 4” victaulic couplings
2/21/24 Confirmed by Chris for 2/26/24 at 8:00am DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspections (4) Wet (1) Dry Deficiency: Leak on 1” pipe and union in electrical room over by maintenance garage. Will need: 10’ of 1” pipe. (1) 1” union. Deficiency: Sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: Sprinkler system is due for five year internal obstruction investigation piping. 2- 4” victaulic couplings Deficiency: Sprinkler system is due for internal inspection five year fire department connection check valve. 2- 4” victaulic couplings Deficiency: Sprinkler system is due for five-year Hydro test of fire department connection Deficiency: System number two is due for five year internal obstruction investigation. 2- 4” victaulic couplings Deficiency: System number two is due for gauge change. 1- sprinkler gauge Deficiency: Dry pendant heads in cooler and freezer of administration building are to be removed an
Sprinkler Inspection 1/11/24(TJV)- Mike G confirmed for 1//17 **Customer would like all inspections coordinated at the same time... fire alarm also needs to be coordinated with the customer's elevator company (customer reaches out to elevator company then will let us know when he is good to schedule the other inspections) [KR] Ann Wet Sprink Deficiency: Sprinkler system is due for internal obstruction investigation. 1- 4” victaulic coupling Deficiency: Sprinkler system. Fire department connection is due for Hydro test. It is a Stortz connection. Deficiency: Sprinkler system fire department connection check valve is due for five year internal inspection. 2- 4” victaulic couplings
1/4/24 Confirmed with Monica for 1/8/24 at 8:00 DH 12/26/23 Tentative date for 1/4/23 DH 12/19/23MV Emailed Monica with new inspection date. They are close until January 2nd 12/11/23MV Emailed Monica regarding inspection date 12/14, Monica would like a different date. Sprinkler Inspection Annual Sprinkler Inspection (1 Wet Sprinkler System) Deficiency: There is no evidence of five-year internal inspection of fire department connection check valve and fire department connection piping Hydro testing. The fire department connection check valve is pinned behind a garage door track this check valve cannot be inspected or removed unless door track is moved to accommodate getting in that space please make note the customer should be made aware of this condition Deficiency: System is due for five-year internal check valve inspection for fire department connection but the rollup door at the back of the building is obstructing the check valve and if roller is not removed valve cannot be accesse