2019 Amana Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain was clear and draining at this time UV lamp is on but past the replacement date Blower motor and wheel were acceptable Blower wires are starting growth Biological growth Evaporator coil was acceptable 2019 Amana Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed the condenser coils from the inside out Recommended compressor saver, UV lamp replacement or upgrade and attic tent