1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for granbury, tx

Rated 4.8 out of 5 stars based on 495 customer reviews

AC unit installed

Jani Tyler

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing all around

everything from setting the appointment up to having them out was a dream will definitely use them again if anything else happens

  • Overall Experience
  • Quality
  • Price
  • Convenience

Unbelievable service

Alex is the Best, didn’t have an issues with the system, He ended up driving an hour to walk me through changing the filter in the attic, felt really bad for that, but He handled it graciously and was extremely understanding about the misunderstanding

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic, educational and informative

Helped provide great options and resources on the things we needed and desired. Great input and professionalism.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Kind and helpful service on short notice!

Knowledgeable, friendly, efficient service. Mark D thoroughly inspected our indoor and outdoor HVAC units, quickly diagnosed the problem, and had the units up and running in under an hour. Much appreciated on a hot day in Texas in August!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Super knowledgeable, nice, professional and clean. Very helpful. A great experience all around.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very personable and knowledgeable. Mark was informative and customer service was a top priority.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

Awesome job and courteous tech.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quality company! Outstanding service!

Outstanding service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional staff

From the ladies that answered the phone, to the gentlemen handling part orders and most especially the tech named Mark, this company stands out as a class act service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Repair

Yeah, meal was very efficient came worked on the machine fixed many things wrong with it. Replaced a coil and now has ordered a new part for the inside unit which controls the airflow said should be here by Friday very informative and let us know exactly what’s going on.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Mark was Great!

Mark was progessional and explained the issue with my AC unit very well. He completed the repair in less than an hour.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great technician

mark is very personable and we look forward to using him again. Thank you for your service to our country Mark.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

A great customer experience. Justin was very knowledgeable and communicated well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for granbury, tx

Mark D.

Mark D. Job Checkin

Two system tune up performed today both systems installed in 2008. Main unit condenser replaced last year. All amp draws are within tolerance. Refrigerant levels are in range. Both outdoor units were washed and waxed.


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Found board blown in mini split due to power surge. Recommend replacing mini split due not being Able to swap boards and system still communicating. Recommend a surge protector also installed to save future systems and appliances inside the house. Scheduled 12-3


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Changed out defrost board on system to ensure prop operation in heat mode due to df2 terminal breaking off


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Trane evap coil M/n Tem6a0d60h51saa SN 163135py2v Tech found that the system is low Tech found the the evap coil is leaking


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Upon technicians arrival, technician found unit was freezing up technician found that the blower was not kicking on. Technician found that the blower would spin when technician would jump. It technician replaced capacitor.


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Upon arrival tech found that the system is undercharged tech looked for a leak and was unable to fine one at this time. Tech talked to home owner to see what they wanted to do he needs to talk to wife before anything. Home owner stated that the system has always struggled tech believes that it could be that the installers never charged the system correctly in the first place


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Upon technicians arrival, technician found drain switch to be going off. Tech Unclogged drain , as well as reset wet switch system is running properly up to technician standards.


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Needs a defrost board. Completed tune up. Washed coil and checked amps and all electrical. Serial number 1512190821 Model number GPH1448M41


Alex  D.

Alex D. Job Checkin

Found primary drain to be clogged and tripping safety switch blew out drain line and vacuumed the water out of the secondary drain pan Unit is now functional left on in cooling Also informed the customer of how to perform preventative maintenance on the drain line with bleach or vinegar and warm water The technician who performs this customers first tune up will want to bring pan strips to help make sure this does not become a recurring issue


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Found hard start kit had gone bad. Replaced under p&l and got system running. Had an 04 code on arrival. Pulls 9 amps on start up.


jani.gonzales@acgenius.com

jani.gonzales@acgenius.com Job Checkin

Replace downstairs system with 30k upflow heat pump keep current filtration includes code kit


Mark D.

Mark D. Job Checkin

Customer is aware that drain safety switch has been bipassed and there is currently no safety switch on the system. Wet switch had failed and was preventing the system from operating. Technician bypassed the wet switch to get the air going. System running and cooling the home upon departure.


Mark D.

Mark D. Job Checkin

Installed UV bulb replacement, condensate drain pan treatment and an IAQ 300 germicidal system. Performed function check. System running normally at time of departure.


Mark W.

Mark W. Job Checkin

Fix tmp on both water heater Fixed tmp line in main house and in pool house. Also put trap on ac in pool house. Main drain and auxiliary drain are switched and can not fix unless we remove indoor unit


Mark D.

Mark D. Job Checkin

Arrived to no cool. Amana gas furnace with straight cool condenser installed in 2020. Discovered an "04" code indicating a locked rotor. This states that the compressor had a failure while trying to start. Installed a compressor saver to help the system start up more efficiently and performed function check. Refrigerant levels are in range. System running and cooling upon departure.