Nathaniel was a great electrician. He solved our problem and answered our questions. He even swept up a small mess that he didn't make. Just great customer care as always. also I would like to promote Hobsons membership plan it made this visit free. Thanks for convincing me to join last year.
Overall Experience
Quality
Price
Convenience
Our A/C broke down and we immediately called for service. We were given a same day appointment, on a Saturday, and within two hours the technician arrived and the system was repaired. We were advised when the technician was on his way and his arrival was as stated. He was courteous, knowledgeable and professional. You could not ask for this situation to go any better.
Overall Experience
Quality
Price
Convenience
When tech left it started getting warm in here I set air at 70 but it just got warmer right now it is 79 degrees in here.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Was very respectful of property. Knew when he was going to arrive.
Overall Experience
Quality
Price
Convenience
I like the service, the detailed pictures of my system tune up, and this is the 2nd year Garrett has been our tech. Companies that retain employees usually have happy employees which leads to better service. Not to mention Garrett is friendly and doesn't try to push sales on you.
Overall Experience
Quality
Price
Convenience
Garrett Y , excellent service , very knowledgeable, we were very comfortable with him and made us feel confident that we were getting our furnace checked out correctly and throughly,
Overall Experience
Quality
Price
Convenience
Colby checked everything out and confirmed system was in good condition. He was courteous and cleaned everything up before he left. We will always request him as our service tech.
Response from Comfort Experts Inc.:
Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.
Overall Experience
Quality
Price
Convenience
Absolutely wonderful service. I am so glad we found Comfort Experts. Would highly recommend.
Overall Experience
Quality
Price
Convenience
He was very sweet ,accurate, n explanatory. Told me the exact part I needed for my heater. I'm quite happy with the services I had with this company.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Michael was very professional and explained my choices in a way that I could understand.
Overall Experience
Quality
Price
Convenience
We talked for some time , getting answers from Mike , seem to be very knowledgeable
Overall Experience
Quality
Price
Convenience
He was friendly , polite , We are not happy that we have to wait around all day ! We are always the LAST one of the day , I do not understand why you can not give a morning or afternoon ! That needs to change , we have other service contractor that come and they give us a morning or afternoon appt time ! We have things delivered and they can give us a morning or afternoon appointment time !
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Service eval Failed condenser control board is running the compressor with no Y call present No updates or error codes present in cool cloud Ordering new control board
On this job I looked at heating and cooling sides of the system. I'm happy to report that both test in tolerance. Heating 100° above ambient Subcool 9 Super heat 15 System has biogrowth and high in rush. Could use uv system and easy start
Her compliant was a loud noise coming from air handler. After taking blower apart I see no issues blow wheel is not loose and motor has no burn marks.
Come to job for electrical inspection and ended up replacing two fixtures with customer supply fixtures
Today returned to clean condensor. Freon level are good 14 super heat. Cap is in tolerance. System is back online and ready for cooling.
Today I looked at both heating and cooling. I'm happy to report the system test in tolerance. Turning on em heat did set off the smoke alarms. The is because the strips had dust on them. This happens and is normal.
IAQ estimate Installed IAQ200 and resealed system Cooling at exit
Service evaluation Failed dual run capacitor Replaced under warranties Motors and refrigerant are fine Biological growth present in the air handler declined air quality improvements
Found bad dual rug capacitor at package unit replaced capacitor unit now working properly collected payment by credit card
Performed tune up Washed condensor and tightened connections Replaced filter Delta 18 All cooling and heating components are in tolerance Installed Soft start kit - Starting amperage from 124 to 22.5 (average) System left on cool at exit
Found condensing coil completely clogged cutting out on high pressure cleaned condensing coil unit now working properly Freon levels good
Upon arrival for evaluation I found outdoor condenser to not be coming on, I checked voltage and had high voltage but not low voltage. I then checked indoor and it had a safeT switch installed but there was no clog. I checked 24 voltage path and everything looked correct I then bypassed safeT switch to check function and system started working. I then tested safeT switch and found it to still be operating as it should I then checked drain line and found some buildup inside line that was causing safeT switch to trigger and cut 24v circuit I cleaned out gunk and rewired safeT switch and system stayed operational. Checked drain line with water and there was no clog just that little bit of gunk causing the sensor to go off. System started cooling and operating as it should System left on cool upon departure.
Upon arrival for evaluation homeowner had system off because outdoor condenser was not coming on and he didn't want to cause damage He mentioned that he reset indoor breakers and outdoor breakers to unit to see if that would fix it and no change I started my turning unit on and checking indoor unit to see if I had power and fan once I verified that I did I moved to outdoor unit Upon arrival I flipped disconnect and removed service panel Flipped disconnect back up and found that I had an L6 error code which led me to the capacitor I checked capacitor and it was very out of tolerance called dispatch to check warranty and found that homeowners have PnL still so I replaced capacitor under warranty and went to turn unit back on Control board was still showing L6 error code so I verified again that capacitor was good which it was so I went inside and reset unit from air handler. After delay condenser kicked on and system started cooling I checked Delta and had 21° of cooling Left system