Great service. Very efficient and very courteous.
Cody did a great job explaining everything to me got the a/c back up and running quick
Professional, answered all my questions and took his time doing so, and just a very pleasant employee.
Jani and Daniel did a very professional job from start to finish. Very kind and respectful as well. Very happy with our clean air ducts and ready for another hot summer!
On this job I looked at both heating and cooling sides of the system. Last time I was out I added some 410a. The system doesn't need any today and has a 9 subcool. The system td in heating is over 30. I change both filters and system is clean. From what he tells me he runs his system as little as he can. The system is in good health. I do recommend an easy start for outside.
. We will install a pex stop on hot side at kitchen sink
On this job I checked both heating and cooling sides of the system. Heating is in tolerance making suction temp of 122° and td of 30°. The system works equally well in cooling td is 20. The system is now clean and has a new filter in it.
For this super tune-up I inspected the customer's furnace and condenser. The customer's germicidal UV bulb is burnout so I recommend replacing that bulb, or to save money in the long run upgrade to an IAQ 200 UV sanitation system that will kill any biologics that are circulating in the home and provide the customer with cleaner indoor air. With the upgraded UV system it comes with a lifetime warranty on the power supply ballast and a 3-year warranty on the bulb itself. The dual run capacitor on the condenser was out of tolerance by more than the recommended 5% reading 20 microfarads out of 45 microfarads, that will need to be replaced before summer time comes and order for his compressor to run and provide the home with cool air. Additionally with the system being 5 years old I recommend adding a hard start kit to the condenser as this will lower inrush amps on startup and improve the efficiency and longevity of the air conditioning system. The customer will discuss it with his wife
For this super tune-up I inspected the customer's furnace and condenser. All equipment was measuring with the manufacturer specs and running well. I measure the customer's insulation where he had an r-value of about 28 which equates to an average of 8 inches of insulation. I would recommend adding more insulation on top of what he has to help with the thermal barrier which will help in energy costs and insulating the house better. I also recommend installing a UV System into the supply plenum as the customer has dogs and mentioned his son has asthma as well, and the IV system will kill any biologics and airborne viruses circulating in the home equalling cleaner indoor air. Lastly I recommend installing a hard start kit to the condenser to keep amp draws low on startup for the compressor, in turn improving the overall efficiency and longevity of his air conditioning system.
1/14/25 Doesn't have the time today wants to reschedule. I'm pausing this call
Arrive for rec work Replaced heat strip kit System heating correctly with 20 amps per strip Hay pump working fine Refrigerant and Motors good Declined UV upgrade at this time
System works in tolerance in heating mode. It has a 30° td the filter are clean. The system has a little rust build up on the evap coil but I didn't find a leak with my leak detector. I did need to add 35 Oz of 410a. After adding the system makes a 20° td. System is as it should be. The homeowners know this is not a fix and they plan on replaceling the condenosr as soon as they are able.
Arrived for rec work Replaced Transformer Fuse popping immediately Traced to W on heat strip kit Verified warranties Ordering new heat strip Switched membership over as well
Arrived for service Eval Transformer inside air handler blown System incompatible with 3 amp fuse and Transformer Ordering replacement as it is a 5 amp Fuse was not blown
We will cable line thru outside clean out in attempt to clear
I was here for a super tune up the filter was very dirty so changed it out the blower was a little dirty. The system had some biological growth in it. Told the customer. Customer provided a UV light for me to change out. The evaporated coil was a little dirty. outdoor unit capacitor, intolerance and refrigerant within range and I clean the condenser.