Outstanding, old school solution to a new school problem. Leaking sink strainer. Third leak under the sink.
Response from Comfort Experts Inc.:
We're so grateful for your 5-star review! We're pleased that Wade was able to provide you with excellent plumbing service. We understand the importance of a properly functioning sink and are glad we could help restore your drain pipes under the kitchen sink. Thank you for choosing us for your plumbing repairs!
Mark did an excellent job. HVAC tune-up. Very professional. Good customer interaction.
Riley was not only professional but very helpful in his role as a technician.
Mark our technician was a very helpful guy. Showed complete respect and was very educational as he went through the process with us.
I am always thankful for the expertise and knowledge of professional men who are kind and answer questions. Thank you Ian!
Tyler has been here before, twice when we had electrical failures. This time he came out to resolve issues that had not yet become apparent. He opened up @40 plugs and @20 switches to confirm the wires were properly attached and tight. Found loose wires in every room. We sleep better now.
We were having problems with two circuits in our house, they just suddenly quit working. Tyler located the problems, loose terminal connections. He then checked every plug on the circuit and found additional loose connections. One of the plug receptacles needed to be replaced and he completed that task as well. Excellent work, very knowledgeable.
Had a problem with 2 different circuits not working. Tyler located the problem (loose wires at two different electrical outlets). Very strange since this home is only 18 months old. I wonder how many other outlets are waiting to fail? This could have taken hours but Tyler took care of the problem quickly. Excellent work.
Tyler Lawyer arrived on time and was very knowledgeable and professional. It is a new house so he found no problems. He did tighten some of the main panel circuit screws and explained that sometimes the screws become loose from movement/temperature fluctuations.
Mark took his time assessed where problems came from, got back up and going with minimal impact to family when he had a long day
Ian was on time and did a great job flushing and doing annual maintenance on our Rheem tanked water heater.
Scheduling could have been better, waiting from 10 A to 5 P was unacceptable. A text the morning of service narrowing the time to 2 hrs would have been better. Justin was great.
Converted the furnace to LP, sealed the evap coil door, adjusted the blower speed and secured the furnace door.
Schedule for Friday the 18th Approved by GoodLeap
Installed #6 bare copper from main panel bus to j clamp on gas manifold in attic. Gas lines are binded to main panel. Disconnected wiring from hot tub. Capped wires and removed from breakers.
Tech found contacter pitted up replaced contacter and unit kicked on
Htu completed, heat exchanger acceptable. Blower motor is a little dirty, blower motor is operating extremely unbalanced and causing airflow issue, blower capacitor has failed Compressor saver failure, surge protector needs to be replaced Replacement blower motor is wider than original, going to return with new bracket and swap out blower motors Evap coil is dirty Recommended, cleaning While inspecting underneath home I found some wiring issues that need to be addressed, they are unsafe Also found a panel that hasn't been weatherproofed and wire that need to be in seal tight, as well as an outdoor light with romex completely exposed. When I return to complete last bit of rec work I will also give estimates for electrical. System is on and operating properly.
2016 3.5t hp attic horizontal. Expired manufacturers warranty- verified. System pushing auxiliary heat. Leaks detected in evaporator coil. Blower wheel has heavy buildup. Blower capacitor below manufacturers tolerance. Return duct falling apart. Poor duct design with multiple 90° angles. Disconnect prongs show visual energy distress. Compressor inrush amperage exceeds manufacturers specifications. Condenser fan motor amps exceed manufacturers specifications. Condenser fan capacitor below manufacturers tolerance. Primary electrical control contractor has extreme scorching. Refrigerant levels are below manufacturers tolerance. After sitting with and sharing all pertinent video/photo evidences of the systems performance, wife called husband and I spoke to him the same. CA appointment set 2/13/25 @6pm. Customer service ran a pre-approval. Wife works for a hospital so please ensure membership benefits and discounts where applicable. No IAQ product. Duct redesign is appropriat
Warranty call. Resealed basket strainer installed by us in 10/24.
Came to job for membership visit and checked everything and explained everything to customer and informed him on surge protection and what it does and he might do it in the future
Heating tune up performed today on a straight electric furnace with a straight cool condenser installed in 2022. All electrical connections are tight with no corrosion. Heat strips are pulling proper amperage. All relays and safeties are acceptable. Ecm blower motor is acceptable. Blower wheel and evaporator coil are clean. All temperatures are within range.
Pulled an reset toilet with new wax ring to fix leak Cst emergency shut off and toilet supply line needs to be replaced cst wants to hold off at this time
Upon arrival air handlers breaker was off, turned heat pump on and is operating efficiently Cst has a toilet that is leaking and wants me to come back to pull and rest with new wax ring
2021 Amana airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Uv system if functional but lamp is past replacement date Heatbstrips were functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable 2021 Amana heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv lamp replacement or uv upgrade, declined work for now. Will follow up through phone in one week
Replaced draft inducer motor under P&L warranty. Performed function check. System operating properly at time of departure.