for this job, I did a cooling tuneup. Delta was good. Current renters replaced filters themselves. Filter has a hole in it. Suggesting to the property owner to update filter box. Drain lines were good. At the outdoor unit. Capacitor wasn’t check. In rush and running amps were good. Washed out coil and system was running and cooling when I left.
Arrived for STU replaced filter Drains clear Installed IAQ300 with pan strip Cleaned coil Could not clean blower due to mounting chain in the way Furnace components fine Washed condenser coil Motors, capacitors, and refrigerant fine Wrapped low voltage wire in electrical tape and conduit due to chew marks
Came out to complete Rec work for Garrett Rick work consisted of replacing the suction service valve on an Amana unit that Services the bedrooms in this home removed replaced pressure tested pulled a vacuum added refrigerant tested it in cool mode everything is functioning as it should 10° sub cool 15° super heat I am pausing this call so the office can collect payment from the homeowner
For this evaluation the customers system was only blowing out warm air and the low pressure switch was tripped because it is completely flat on refrigerant and leaking from the saturation line service valve, so I was unable to add refrigerant or leak search. I spoke with Shantelle, the homeowners daughter about what I found. At this time she wants to fix the problem but discuss with a CA about what it would take to replace the aging system.
I was here for a super tune up system filer was a little dirty but still good blower had some dust on it found screw in blower housing I removed it heat Exchange looks good system had amps on the inducer in tolerance out door capacitor looks good all amps in tolerance refrigerant in range condenser clean could not ch3dk Humidifier ladder did not reach. Into the attic customer might was someone to come out and talk about a new system
On arrival system running and cooling producing 20 degrees delta. Superheat was an 8. Condenser coils dirty in heat of day system likely locking out on high pressure. When I left system running and cooling.