1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for godley, tx

Rated 5.0 out of 5 stars based on 14 customer reviews

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Great tech awesome guy great attitude very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Justin was great! He explained what the issue was and what he needed to do to correct it. He is polite and respectful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent! Helpful when others were not available!

Thanks for the help on such short notice! Great service as well as very professional and kind. Thanks again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional.

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Communication

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service!

Kellen was an awesome tech! He was forthright, honest, prompt, and offered many options!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Extremely professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Responsive and professional!

I appreciated the straight down to business and professional attitude! Tyler got it done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

great technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for godley, tx

Kellen M.

Kellen M. Job Checkin

2020 straight electric 4 ton download closet. System is losing performance quickly. Homeowner claimed $800 electric bill. System was installed before they moved in. Oil spots found on evaporator coil. Evaporator coil is extremely restricted from proper airflow. Heavy biological growth. Blower wheel is heavy with dirt and dust build up. Compressor inrush Amp exceeds manufacturers data tag. History or capacitor replacement. Condenser has foliage around coils. Husband is a police officer and was on duty. Family is leaving for vacation. Wife set appointment for CA on 6/26/24 @9am to discuss a more reliable and efficient system. Explained to wife about unblocking the return closet to maximize airflow to unit. We discussed system decontamination and warranties. System is functional but reduced in performance.


Tyler L.

Tyler L. Job Checkin

The panel looks good but they were having trouble with a GFCI outside tripping the TV inside every time they use the hot tub I have made an estimate but the homeowners were not home at this time


katie c.

katie c. Job Checkin


Tyler S.

Tyler S. Job Checkin

06/03/24 TS- cut 3/4" AC drain line and installed a union, to help future services. Ran snake down 2" drain line and cleared clog. Poured a few jugs of water down the drain and it doesn't back up. When charging her credit card that's on file it would instantly accept charge but then change on the front page that it was payed. We ended up trying to charge 3 times. Each time it was accepted but the system would change shortly after. No idea why. Card on file that ends with 1936 is what we charged on.


michael.martinez@acgenius.com

michael.martinez@acgenius.com Job Checkin

Arrived to system no power Wet switch sensor activated - system off Delta is 18 System running in cool at exit Homeowner needs appointment for estimate to clear home line that is connected to HVAC line. Has slow drain and build up Homeowner schedule is open throughout week Call to schedule day and time. As soon as possible


Lisa M.

Lisa M. Job Checkin


Mark D.

Mark D. Job Checkin

Trane heat pump with air handler installed in 2022. All electrical connections are tight with no corrosion. Ecm blower motor is acceptable. Blower wheel and evaporator coil are clean. Refrigerant levels are in range. Compressor and condenser fan motor are acceptable. Dual run capacitor is within spec. Outdoor unit was washed and waxed in order to protect it from sun damage. Highly suggest adding a compressor saver to help with the reliability and efficiency of the system.


Derek.bryant@acgenius.com

Derek.bryant@acgenius.com Job Checkin

All plumbing is in great condition no leaks or broken fixtures at this time House is 2 years old Prv present in yard 2 bath home Electric heater in garage with expansion tank up to code


Ian C.

Ian C. Job Checkin

During inspection I found biological growth build up inside of air handler, and on evap coil Cleaned coil and drain pan, installed drain treatment Drain wasn't installed properly causing stoppages to keep happening Repaired drain and installed drain switch properly System is operating efficiently and is clean


Brock S.

Brock S. Job Checkin

Customer wanted quote on duct cleaning of system. Is found both supply and return plenums to be dirty, Evaporator coil dirty and blower wheel dirty. Also found that box filter was not filtering out all dust, Causing dirty system. Recommended a level two duct cleaning and filter media upgrade on 20x25x4 box filter. Customer would like to go through with repair, But was unable to give date. Will call the office tomorrow for scheduling. Found no other issues at this time.


Kellen M.

Kellen M. Job Checkin

2021 evaporator coil. 2007 heatexchanger. 2009 compressor. Replaced filter. Compressor is inrush amping over LRA. Expressed to homeowner the issues. Husband was not home to speak to. Potential condenser replacement, homeowner will wait.


Justin  P.

Justin P. Job Checkin

AC Maintenance. Airhandler Checked and tightened all electrical connections Evaporator coil was heavily compacted with dust dirt and biological growth Blower wheel has dust build up Drain was clear and draining Heat strips were functional and within manufacture range Straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Recommended coil cleaning and compressor saver


Derek.bryant@acgenius.com

Derek.bryant@acgenius.com Job Checkin

Open walls to check/ insulate piping manifolds Cut wall to shower manifold, had main lines running there first. Pipes were not insulated on the inside wall, shower base had empty space to the outside wall potentially causing cold draft to manifold area. Filled with spray foam and insulated the water pipes.


Jose  G.

Jose G. Job Checkin

Replaced fiber cement siding and painted it to match.


Tyler S.

Tyler S. Job Checkin

03/08/24 Tyler - new build area no issues