Nate was every good at finding the problem and getting it fixed
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Great Tech provided quick accurate, assessment of the project and came up with a price right away! Really nice guy too.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Hunter is great. He has been my tech before and as always he is professional, articulate and explains things in layman’s terms.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Professional, knowledgeable and attention to detail. Fixed the problem while giving me some insight on the overall process. Much appreciated!
Overall Experience
Quality
Price
Convenience
Ian was professional and explained the issue to me so that I could understand it. Really appreciated his level of service. $400 total seems like a lot for a capacitor swap.
Overall Experience
Quality
Price
Convenience
very professional and cleaded up afterwards.would recommend their work
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
He was professional and respectful.Very happy with the service.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
2018 Trane Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Drain has no drain safety Blower motor and wheel were acceptable Blower wires and assembly have heavy biological growth build up Evaporator coil has slight biological growth build up Supply plenum has biological growth build up 2018 Trane Heatpump Checked and tightened all electrical connections Dual Run Cap was within manufacture range Primary electrical unit was acceptable Defrost board was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended Level 2 duct cleaning, UV 300, drain switch and compressor saver
Super tune up performed today on a two system home with Goodman gas furnaces installed in 2021. All electrical connections are tight with no corrosion. Gas valve, burners, igniters and heat exchangers are all acceptable. Blower wheels and evaporator coils are clean. Compressors and condenser fan motors are acceptable. Both outdoor units were washed and waxed. Suggest adding a compressor saver to each outdoor unit to help with the efficiency and reliability of the compressor. Also suggest adding. An IAQ 300 Germicidal System to help improve air quality.
10/9/25 Site walk through with Mark W. Plumbing estimate accepted. Will return Tuesday with Mark. To complete phase 1 of project. APPOINTMENT already made.
Arrived to no cool. 04 code on outdoor condenser indicating a locked rotor. Outdoor unit is very dirty and is restricting air flow across the coil. A tree is growing over the condenser that is further restricting air flow. Tree needs to be cut and unit needs to be washed. Compressor saver has failed and needs to be replaced. Performed a hard reset on the system and it was able to start. System running and cooling the home upon departure. Customer does not have water to the home at this time and the coil was not able to be washed. Customer said she will call the water company in the morning and get water back to the house. She will call us to come out and wash the unit when she has water back to the house.
Find mini split low on charge only 5 months old. No warranty on charge. Tighten connections and charged systems the best I could
I have completed putting up the lights and put in a surge protector
Estimate accepted to install 100A feeder to garage. New member. Customer is going to communicate with us when builders are ready to pour concrete. We will install conduit and did trench before pad is laid. Contractor contact info is 844-941-0999. Roy Rodriguez. Wolfsteel buildings. Tentatively customer thinks first step will be ready beginning of September. Will require 2-3 trips. Disconnect and reconnect will be scheduled at first visit. I spoke directly with concrete contractor and they will call me 2-3 days before concrete is poured. Customer paid 33% down payment. 33% will be collected after conduit is installed. And final 33% will be collected at final switch over.
Completed cooling tune up on a 9 year old heat pump. Pressures are good has biological growth in air handler recommend a uv light for that. Outdoor system is running within manufacture spec.
Found contactor was burned up and not passing 240 volts thru contacts. Ecm fan was running replaced contactor and compressor came on. Believe contact was burned up from the shorted float switch causing it to close and open suddenly creating heat
Replaced thermostat and found that the ecobee was shorted due to a shorted float switch. Replaced float switch and verified system was cooling properly watched for 20 mins and verified pressures.
When technician arrived system was cooling. Homeowner informed me that ecobee randomly went to heat mode has done it in May prior customer is going to buy a different Wi-Fi thermostat and have us install. Checked drain line checked filter and everything is working as manufacture spec
Quoted a level 5 24k whole home automatic generator for $21,000
I will return on Saturday to install two new customer supplied lights in the kitchen
I haven't found what exactly might be the problem but it seems that 1 of the smoke detectors is defective so the home owners are gonna replace it them selves and try to see if that works