Abel was great! He took his time and was very thorough! A very friendly guy and more than happy to answer all my questions!
It always seems to be a problem on the weekend! Thank you Tyler for coming on Saturday and checking out my leaky toilet!
Tyler was very thorough in diagnosing the source of a leak and the cause of a sewer water noise. It’s all good and was reasonably priced. Thank to both of the gentlemen who came out.
The staff and technicians at Comfort Experts are so polite and professional. They keep you informed and are knowledgeable. I trust their service. Derek came promptly today and is moving my project along. Thank you.
Mark was not only expert at all phases of the job, but he almost made me an expert too. Informed me every step of the way. Went above and beyond in all phases of the project. Very courteous and polite. You are lucky to have him!
I appreciated Hobson coming out on the weekend. Justin did a great diagnositic and will come back with needed parts to finish 1st thing in the morning. Very nice; very thorough.
Cody is a great tech! He was very professional even in 100+ temperatures! We were very impressed with this young man - very polite, very informed and very intelligent. You have a great employee here! Thanks!
Service was great! Cody & helper were very professional and explained everything well. Thanks
The guys that came out were very good Zack was super got us going. Y’all got out quick and my A.C. Is cold thank you very much
He was super awesome, professional and is going out of his way for us!
Comfort Experts come out whenever you call! Thank you, Mike. Excellent service.
Wyatt our technician was friendly, knowledgeable and very thorough. Great company and great people!!
Upon arrival techs installed unit surge protection, removed old r410a, tvx, installed new tvx, did a pressure test, pulled a vacuum down to 500 and charged the system to its proper readings system is up and running at this time
5/29/25 We will install a new prv by meter using existing box. This will include new service valve at meter We will return with material tomorrow 5/30/25 to complete the job. Will need to dig up meter and existing prv and replace
When I arrived the homeowner said he requested a phone call before we came out here. He reset the breakers last night due to a power surge and was able to get the ACs working and wanted the phone call so we didnt waste a trip. He also wants to make a note to please call 9724670900 that is his number, not his wife's number due to her not feeling well. I talked to him about surge protection for the units that tripped he asked if we could bring 2 out when we come repair the other unit, he would like one on the 5 ton and 3 ton unit not the bedroom unit. He also would like a call to know when that part will be in because he does not live here and it has to be scheduled for someone to meet us here.
Upon our eyeball technician found unit was freezing out due to thermo expansion valve causing the blow and not turn on suffocating it technician has system off until parts coming
Upon arrival text started with main house technician found that system three has a bad TXV that is clogged with a low superheat as well as a high subcool technician talk to homeowner about it homeowner would like to repair the system he would love for his systems as we remain r 410a tax headed to guest house where technician found everything to be working up to technician standards all units have been washed and waxed technician is going to have to return to install TXV
Please schedule in the morning first call for customer provided tankless no inspection county
Changed out components on tankless water heater tested for firing tankless is working
Arrived to no cool on the larger main unit installed in 2017. System has shut off due to a tripped wet switch. Cleared the drain and added a drain pan treatment to both units both systems running and cooling upon departure. Recall on previous technician for not checking the drain lines.
105000180 part number for igniter And heat exchanger is covered with dust and debris as well Order parts from Winston will call when they arrive Model-rl94i Serial-flca-130272
2012 2.5t hp closet upflow. Manufacturers warranty expired. Primary pan full. Leaks detected in evaporator coil. Oil streaks present. Freezing. Inrush amperage on compressor exceeds manufacturers specifications. Refrigerant charge below manufacturers specifications. Hard start kit pressure plate blown. Capacitor below tolerance. Sat with homeowner and shared all video and photo evidences. Explained in detail the energy usage, performance and saftey of the system. Homeowner is aware of the need to replace system. CA appointment set for 5pm Saturday 4/26/25 Systems functional but diminishing in performance.
Upon arrival tech found that the wet switch had gone off due tech found that there was nit cardboard under wet switch Unit is on and running properly
Arrived to no cool. Carrier heat pump with air handler installed in 2022. Unit was freezing up due to no airflow. ECM blower motor had failed most likely caused by a surge during a storm. Performed hard reset on the system and it was able to start up. Checked all amp draws and refrigerant levels. System operating normally at time of departure. Customer has signed up for the Home and Budget Protection Plan.
Technician arrived to customers home. Technician ask homeowner questions about home. Technician graph tools and started an airhandler. Technician took electrical readings and changed filter. Technician continued to condenser unit outside. Technician wash condenser unit and took refrigerant levels all in range. Technician to took electrical readings all in range. Technician wax the condenser unit and talk to customer about recommendations.
Need to order regulator for generator under warranty