Great guy and very friendly. My husband offered him dinner and he said that we were nice people. Thumbs up!
Extremely helpful. Went above and beyond for us to make sure our system was running optimally. Thank you for your dedication. Definitely 5 star service.
Easy to talk to. He knew what he was doing and made the visit great
Daniel did an excellent job. He was very thorough and professional.
Good overall I think the text messaging is overly done (confirming the confirmations that have re-reconfirmed 🤬(clerical not the service tech!)
Michael R and the Comfort Experts team were very helpful in their suggestions, recommendations and service of my two HVAC systems.
Technician, Aaron Aaron Wood qiuckly diagnosed the problem and replaced the malfuncting part. He went-on and checked the function of the rest of the system.
Tyler was great, knowledgeable and kind. Fixed our sink really fast. Would highly recommend
On this job I inspected the gas furnace and cooling side of the system. The only part out of tolerance was a uv bulb that she is not interested in changing. The cooling side has a td of 20°. Heating td is 30°. System could use an easy start to improve amp draw and increase longevity. Today she going to the home and bugged plan.
11/29/2024 BrianH installed pilot assembly. Lit pilot and tested water heater. Water heater functioning normally at this time. Water heater is leaning toward middle of closet and needs to be leveled and supported to prevent possible significant flooding, disconnect of flue assembly (Carbon Monoxide issues in home), or fire. Need a plumber to return tomorrow with thermopile and completed recommend work How water heater is down
Arrived to water heater producing 0 heat Status light code off - code not shown Gas to furnace operational Water heater ignitor fails to spark Manuel pilot press/spark fails to operate Refered homeowner to plumber to be scheduled by office System off at exit
Arrived for super tune up Washed condensor and tightened connections Delta 22 Filter did not need to be replaced at this time Homeowner will replace filter All cooling and heating components are in tolerance Reccomended surge protection Reccomended IAQ200 Reccomended compressor saver kit for high LRA System left on cool at exit
On arrival furnace failing at flame sensor. Replaced flame sensor and ignitor and it is running as intended.
Arrived for HTUx2 Filters fine No sediment taps on either Furnace Upstairs Furnace inducer motor nearing failure and should be replaced Comfort Advisor 11/22 9 am due to age, cost of repairs, and refrigerant phase out
Arrived for super tune up All cooling and heating components are in tolerance Replaced filter - more electrostatic inserts will be ordered by homeowner Delta 23 Refrigerant is good Reccomended whole home surge protection Reccomended IAQ200 System left on cool at exit
On arrival system running but not heating. Found the gas line closed preventing the furnace from heating. Once gas turned on system ran and heated with no issues.
I was here to perform a tuneup on systems. Both condenser capacitors are out of tolerance. I changed out the downstairs capacitor. I change the filter for the upstairs. system very clean but ducks need a duck cleaning refrigerant within range amperage and range delta looks good UV bulb good for another year
I call but ended up leaving a voicemail and gave all three previous estimates as emails
For this super tune-up we inspected the furnace, coil, and condenser. The flame sensor was corroded and the capacitor was out of tolerance. Additionally when we gauged up we had a 33⁰ SH which is indicative that the TXV has become restricted and can impact the performance of the air conditioning during the cooling season. We talked to the customer about the difference in cost of repairs versus replacement and at this time the customer elected to replace the capacitor and Flame Sensor for now and speak with her son about replacement.
10/29/24 TS- replaced guts of frostproof hose bibb outside backyard.
Unit inducer motor is in tolerance filter was clean all safety and igniter working uv bulb still working helped customers with nest so it won't change temperature at random
On arrival system running and cooling as intended. Furnace ran with no issues. Uv bulb was in need of replacement, with customers permission I installed an iaq200, a drain treatment strip and did a complimentary sanitizing spray.