1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for crowley, tx

Rated 4.9 out of 5 stars based on 107 customer reviews

Great service

Michael did a great job except the issues with the system were above his pay grade so he called the big guy to look at it . Hopefully it won’t be anything major !!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service. Very orofessional

Alex and Keynan were the best! They worked in the pouring down rain but they kept plugging along and got us up and running They were the best!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great teamwork

Very polite and hard working . They worked very well together !!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Great experience 10 and 10 would recommend a very knowledgeable fast and honest

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

1000000 out of 10

Colby was literally one of the best people ever! He had such a great attitude and made this experience amazing. My daughter was asking him a million questions, and he took it with such kindness. He truly felt like part of the family by the time he left.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Ryan was very courteous and respectful. His diagnosis and explanation of the problem was complete and comprehensible. I appreciated his visit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service as always!

There’s a high level of standard I’ve come to expect from Comfort Heating & Air, and Michael did not disappoint! Raised the bar.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Received service same day as I called, Adam was professional, knowledgeable, and fast with the work he completed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Outstanding service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Jonathan was very professional and took care of our problem.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for crowley, tx

daniel.andrade@acgenius.com

daniel.andrade@acgenius.com Job Checkin

For this job I performed a evaluation. Upon arrival homeowner stated that they had an electrician come out to their house because the AC kept tripping their breaker. The electrician told them that there is something grounded and it's coming from the HVAC side so they had to have someone come service it. I tested the compressor continuity at each point and showed the homeowner that the compressor is in fact grounded. Recommended either having rec work done for a compressor to be changed out if the owner is able to find warranty or for a comfort advisor to give an estimate on a new system. Homeowner agreed to have a comfort advisor come out to give them an estimate so they can weigh their options. Comfort advisor scheduled for Wednesday 7/9/25 homeowner is unsure of their work schedule and make call back to reschedule the comfort advisor. Thank you for choosing for experts, have a great day!


daniel.andrade@acgenius.com

daniel.andrade@acgenius.com Job Checkin

Or this job I performed a evaluation. Upon arrival homeowner stated that they feel like the system has not been cooling as efficiently since last visit but they aren't sure if it's because it's been hotter or is missing refrigerant. During inspection I did not see any significant abnormalities what refrigerant or Delta levels one checked. I use the thermal camera to check the supply and return plenums and could see that there was cold air leaking out of them. I recommended properly sealing the plenums to help air not leak out. The homeowner mentioned that their wife has severe allergies, I briefly spoke about the best option for people with allergies installing a upgraded filter system and a UV system. Lead set for IAQ specialist, to look at system and give estimates.


Jake  S.

Jake S. Job Checkin

Came to job for electrical inspection on townhouse and everything looks great only 4 years old and has GFI protection afci breakers everything it needs to be up to code all the grounding it needs even has a surge protector so house is up to date


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

For this job myself and Colby came back to replace the customers evaporator coil. We took the old one out, brazed in the new one and pulled a vacuum below 500 microns as well as performed a decay test on the system which it held. Charged the system to a 10⁰ Subcool and the system was producing 21⁰ of cool air.


Ryan  M.

Ryan M. Job Checkin

Pricing on this estimate is to locate the source of leak causing the valve box to fill with water. Comfort Experts will excavate the area around the valve box tracking the water line to locate the source of the leak. While excavating we located a 3/4" Pex water line that was not tied into anything, with further diagnostics it was determined to be the water softener discharge line. It had been run into the ground, and left there. *The problem, is the softener system. The system is not cycling properly, causing a continuous flow of water out of the discharge line. In turn filling up the valve box and flowing out to the street.


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

This service call was made by contractor that was working on homeowner's roof found loose 24 volt wire at condenser fixed wire unit now working properly free on levels good collected payment by credit card


daniel.andrade@acgenius.com

daniel.andrade@acgenius.com Job Checkin

For this job I performed a evaluation. Upon inspection I suspected that the system was low on refrigerant due to hot suction line coil. I leak searched the system and found they leak in the indoor evaporator coil. Homeowner has p&l warranty. Homeowner was made aware that they will be a $550 charge for refrigerant. We need to order the evaporator coil and call to schedule when it arrives.


nathaniel.burke@acgenius.com

nathaniel.burke@acgenius.com Job Checkin

Installed new ceiling fan in Living room offered membership.


Mike R.

Mike R. Job Checkin

On this visit looked at both sides of the system. Cooling has a 15° superheat and 10° subcool. The system has a hard start installed by last service company. I recommend removing that and replacing it with a soft start made by micro aire. The benefits list of of this are long. This device has the ability to protect the compressor from surge and increase longevity and reduce inrush by 75% .


michael.martinez@acgenius.com

michael.martinez@acgenius.com Job Checkin

6/15/25 Performed evaluation Upon arrival system was off System operational cooling and heating Cooled room to 72 and set temperature at 78 - system fails to stop operations System will continue to cool - overcooling room Reset control and set cool with Auto fan - updated clock No additional settings on System operational and did not turn off when temperature was satisfied Check communication wires and they are matched - indoor/outdoor Pausing call for Install to return System left off at exit


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Customer was quoted a 48k electric unit for downstairs wife was not in meeting he wants to consult with her first


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Found unit out of freon evaporator coil leaking setting up for comfort advisor to come out tomorrow and give estimate on equipment


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Clear drain unit now draining also found evaporator coil clogged and dirty freon pressures not to spec unit could be possibly freezing up due to dirty coil customer is aware of this left estimates with customer does not want to move forward at this time with repairs charged for clearing drain


Ryan S.

Ryan S. Job Checkin

Replaced faulty air temperature sensor. Now reading temperature correctly. Water is still making its way into airhandler cabinet due to blower pulling the condensation of the coil. The main reason this happens is due to a failed sheen on the evaporator coil wich was just replaced so is highly unlikely, or high static pressure, with a zoned system this is very likely. Found that the bypass damper which is there to relieve static pressure when one of the zones is closed is failed. It will open when a zone is closed but when the zone is reopened it will stay open causing it to recycle conditioned air, causing lower air temps and causing the condenser to cycle off and on more than it should.


Alex  D.

Alex D. Job Checkin

Replace18k mini split