Upon arrival system was off, turned system on and outdoor came on but indoor would not. During evaluation reset breakers and started system, blower came on and off as should multiple times. Checked components on Heatpump and found auxiliary motor starter had failed also found disconnect was broken. Recommended replacement of safety disconnect and auxiliary motor starter. Customer declined safety disconnect but wanted to replace auxiliary motor starter. Left system in heat mode
Called out for leaking hosebib. Sweat off old valve, solder on copper mip adapter and install new silcock. Set up on membership
11/27/24 Installed new gas service and repiped 4 drops. All new plumbing held test. Turned gas on and lit all pilots and tested furnace. Customer has heat and hot water for the holiday. Will need to go back on Friday to button up a few minor details. Will also need to schedule an electrician to bond the system
We will cut out bad pipe and fittings and replace. After repair, pressure test is still showing a leak. I am not able to turn gas back on at this time. Estimates given for new service line and 4 drop repipe. This job is financed We will Trench from meter to corner of home. After excavation we will install new 1"poly gas service with stop and union at house and run new csst gas lines to all gas appliances with new stops and supplies. New gas system will be bonded electrically as per code. All new work will be tested and installed as per code
Customer requests a plumber to come out to perform a pressure test on the gas line. Heating tune up performed today on an Amana gas furnace with straight cool condenser. PSC blower motor and capacitor are acceptable. Blower wheel and evaporator coil are slightly dirty. Attic is very low on insulation. Furnace safeties and functions are working properly. Technician smelled the odor of gas outside by the condenser. Technician turned off the furnace and the gas water heater pilot and watched the meter to determine there is a slow leak somewhere in the system. Requesting a plumber to come out and perform a pressure test on the gas line. Gas was turned off at the meter before departure.
When the indoor control board was replaced it was connected incorrectly on the low voltage causing the air conditioner to come one every time the blower would come on. Corrected the issue and performed function check. System is operating properly in air conditioning, heating, and fan. Recall on me.
Changed out furnace control board. While performing a function check found the PSC blower motor to be overheating and over amping. Replaced 1/2hp, 115v, 1075rpm blower motor and 10mfd capacitor under warranty. System running in cool upon departure.
While system is running the blower will turn off and on intermittently. Losing high voltage power coming out of the control board. Ordering a new control board under P&L warranty.
Valve was off in attic not allowing flow to master bath sinks and shower. On hot side only turned valve on to return flow to bath
Replaced all lines around the water leak with new fittings, insured no leaks and installed laundry sink p-trap
Toilet and kitchen faucet was low pressure due to break on main line flooding system with debris Install new angle stop under kitchen sink and cleared kitchen faucet cartridge of debris No warranty on cartridge clearing. Recommend new cartridge for full pressure Installed new fill valve and supply line in hall bath
10/3. Work completed. Please send N. BURKE if any future electrical work needs done. Thank you. Plumbing lead set to run this afternoon.
PLEASE SCHEDULE WORK FOR THURSDAY 10/3 FIRST APPOINTMENT. BE ALL DAY. 7 bubble covers. 1 2 gangcbubble cover. 8 WP gfcis. 1 wp receptacle. 50' 3/4" pvc. 2 3/4 LBs. 3 90s. Straps. 2 gang bell box with 3/4 kos. Homeline 120. Roll of 12-2. 2- 1/2 inch minis. Customer 2404.70.