Justin  P.

Justin P. Job Checkin

Upon arrival system was not running, Condenser was going out on low pressure. Leak searched outdoor Condenser and Evaporator coil, found no leaks. Added Refrigerant and leak tested again still found no leaks. Added locking service caps, system didnt have any service caps on arrival. notified Customer of issue. Got system up and running told Customer to call again if issue occurs


Justin  P.

Justin P. Job Checkin

Upon arrival Customer stated lineset would freeze up. After evaluating Refrigerant levels and Dual run cap. Washed Condenser and Checked filter. Filter was completely blocked with dust and dirt. Not enough air was getting to the coil causing coil to freeze. Left coil out of system, Customer stated they are getting filters right away Recommended cleaning Blower, Evaporator coil and replacing Blower capacitor


Ian C.

Ian C. Job Checkin

During inspection I found that the indoor unit has lots of biological growth build up Duct work is also extremely dirty Recommend lvl 2 duct cleaning Rose bushes covered the outdoor system, cleaned and raked around system


Mike  S.

Mike S. Job Checkin

Common line to to coresense was severed coresense was tripped and would not reset. Replaced common line and coresense sensor. Fuse on control board was blown replaced now system is on and cooling.


Mike  S.

Mike S. Job Checkin

2022 Goodman Air Handler Checked and tightened all electrical connections Changed customer provided filter Drain had some build up, still would drain poured a gallon of water down Blower motor and wheel were acceptable Evaporator coil was acceptable 2022 Goodman Straight Electric Dual run capacitor was within manufacturers range Electrical connections were acceptable Refrigerant levels were acceptable at this time Condenser coil was slightly impacted with dust and dirt Fan blades and motor were acceptable Washed coil from inside out Cleared debris from inside unit Waxed top of unit Recommended pan strip to prevent future build up in drain Recommended compressor saver Customer didn't have an email can't email estimates


Mike  S.

Mike S. Job Checkin

Customer said unit made a loud noise 2 days ago and has been working since then. System was on and cooling properly upon arrival performed an inspection on the outdoor unit to try and recreate the sound no sound out of ordinary was made during my inspection. I advised the customer to record sound if it happens again that way we can have an idea of how to diagnose.


Ian C.

Ian C. Job Checkin

Cust wants to have her own account Phone number: 936-494-9501 Capacitor failure swapped all systems operating efficiently


Ian C.

Ian C. Job Checkin

Rec work completed


Wyatt C.

Wyatt C. Job Checkin

On arrival system was not functional in cooling mode , reversing valve was not being energized allowing the system to work in cooling. Bypassed to allowing cooling , customer is calling the owner of the property to decide if they want to order a board tried calling them while I was there but no answer.


Mike  S.

Mike S. Job Checkin

2022 Goodman Air handler Tightened all electrical connections Customer has filter and said he would change it Drain was clear and draining, poured a gallon of water down Blower motor and blower wheel were clean Evaporator coil was clean Heating elements were functional and within manufacturer range 2022 Goodman heat pump Dual run capacitor was within manufacturer range tightened all electrical connections Refrigerant levels were acceptable at this time Condenser coil was acceptable Condenser fan blades and motor were acceptable Cleaned debris out of the unit Washed coil from inside out Waxed the top of the unit


david.yates@acgenius.com

david.yates@acgenius.com Job Checkin

Did a membership tune up. Went to the unit it was good besides ducts were super dirty. And blower wheel was too. Offered him the work but he doesn’t have that money right now. Outside u it everything was good and I washed and waxed it


Brady F.

Brady F. Job Checkin

Replaced receptacle. Recommend replacement of pass through panel


Mark D.

Mark D. Job Checkin

Customer wanted an estimate for duct cleaning.


Wyatt C.

Wyatt C. Job Checkin

2016 Goodman Gas Furnace Filter was acceptable Blower wheel needs to be cleaned Blower motor were acceptable Evaporator coil was acceptable Heat exchanger was acceptable Drain was draining poured some bleach down for customer Heating elements were functional Ignition safeties and door safety were functional Electrical connections were acceptable Qq 2016 Goodman Straight Cool Dual capacitor was within manufacturer range Fan blades and motor were acceptable Primary electrical contactor was acceptable Cleaned the debree out of the unit Washed the unit off Waxed the top of the unit Declined work


riley.hobson@acgenius.com

riley.hobson@acgenius.com Job Checkin

Install Goodman 36k elec horizontal 1500 sq ft R11 insulation, slab, disconnect, whip, code kit, drain pan