Overall Experience
Quality
Price
Convenience
Jake installed my new chandelier perfectly! Highly recommend him!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Hunter did an excellent job servicing my my air conditioning unit. He was polite and very thorough.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Hunter and Zachary were both very professional and personable. I appreciated how they honestly explained an issue I had but were not pushy about telling me I needed a part replaced (which I gladly did after getting a detailed explanation). If all of your technicians are like them, you clearly have a great company. This is the first time I used your company and will continue to do so in large part to these two outstanding gentlemen.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Great Technician with excellent feedback and explanation.on the system
Overall Experience
Quality
Price
Convenience
11/17/25 Removed failed Compressor completed Rx11 flush through system and purged with nitrogen. Added suction line drier to the system and installed new compressor and TXV. Pulled vacuum on system and left with a 6 subcool. Also jumpered the reversing valve to always be energized for now. Need to comeback 11/21/25 FIRST CALL TO REMOVE SUCTION LINE DRIER AND REMOVE REVERSING VALVE JUMPER SHOULD TAKE AT MOST 2 HOURS
Came to job to look at a few different things in the house and quoted them to add a plug in hallway also quoted to add light on back porch and change out breakers once they come in the mail
Outdoor TXV shuts down in heat mode. Moved sensing bulb to liquid line and TXV opened once the line temp got above 140 but that is not a fix to the problem. Confirmed failed TXV and coil cleaning needs to be done
I will be back to separate out the lights in the garage from the garage door openers and I will be running 2 lines in the pony pin to add light and a plug The 20th of November is the schedule date for the project
New compressor is Grounded. Per Brian we will need to an R-11 flush of the system and add liquid line drier along with suction line drier to clear any acid or contaminations in the system. NEED TO ORDER ANOTHER COMPRESSOR FOR UPSTAIRS HEATPUMP MODEL - ASZ160241AC SERIAL - 0810201091
Replaced compressor,pressure tested and pulled vacuum changed txv. Charged system to 8 degree subcool. Left with system in cool
Super tune up performed today on a Lennox heat pump with air handler installed in 2020. All electrical connections are tight with no corrosion. Existing UV system was not working and had previously been dismantled. Installed a new UV 200 germicidal system. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Compressor saver was installed in the outdoor unit. Performed a free courtesy check in the upstairs unit. R22 straight electric system installed in 2003. System is low in refrigerant and the system should be replaced. Main system running and cooling the home upon departure.
Super tune up performed today. There is a restriction in the outdoor unit metering device that is causing the system to shut down on high pressure in under a minute. Metering device and filter line drier need to be replaced. Heat pump will not work as it is currently. System will only heat home with he emergency heat strips. All electrical connections are tight with no corrosion. Heat strips are pulling proper amperage. Evaporator coil is dirty and needs to be cleaned. In cooling, the compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Customer declined repairs at this time.
Upon arrival indoor was blowing Heatpump was not functional. During evaluation found board to be throwing low pressure cutoff code. Attached gauges and system was completely flat. Added some refrigerant to system to perform a leak search. Upon adding refrigerant the condenser coil began to hiss indicating a big leak in the condenser coil. Located leak on corner where dog has been urinating. Dog urine is acidic and ate through the aluminum coil causing leak. No longer under warranty due to that fact. Customer firmly stated he's getting a second opinion for the condenser coil that is leaking due to customers dog urinating on system.
Grounded compressor on upstairs system. System is lifetime P&L Did not collect due to uncertainty of parts being found NEED TO ORDER COMPRESSOR AND TXV MODEL - ASZ160241AC SERIAL - 0810201091
Two system super tune up performed today. All electrical connections are tight with no corrosion. Both blower motors are working properly. Systems are clean. Heat exchangers, gas valves and burners are all working accordingly. Outdoor units were washed and waxed. The expansion valve on the smaller bedroom unit is failing. Bulb is not sensing temperatures and valve is not opening and closing as it should. Highly suggest replacing. Neither unit had drain protection n suggest adding a drain safety switch to each unit to prevent water damage in the home.
Performed Tune up on both systems today Checked all components of the furnaces and changed filters. All components working properly. Both UV systems are no longer functioning, talked with customer about more robust and efficient UV upgrades. Checked all Heatpump components and washed condenser coils from the inside out. Recommended UV system upgrades
Came to job to hang chandelier and look at lights and closet
2017 Colman Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain has build up in trap Blower motor and wheel were acceptable Evaporator coil was acceptable Blower wires have biological growth 2017 Coleman Heatpump Checked and tightened all electrical connections Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended UV systems, anti microbial pan treatment
Two system cooling tune up performed today. All amp draws are within spec. Refrigerant levels are acceptable. All outdoor units were washed and waxed. Blower wheel on downstairs unit is dirty and needs to be cleaned. Biological growth is present inside of the downstairs air handler. Suggest cleaning the blower wheel and adding a germicidal light.