1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for aledo, tx

Rated 4.9 out of 5 stars based on 152 customer reviews

Excellent Service

Very informative technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service.

Took his time. Identified a few problems, answered some questions, helped me prioritized what needed to be fixed. Very helpful. Did a good job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great!

Very professional and caring

  • Overall Experience
  • Quality
  • Price
  • Convenience

Above and beyond service

Jake is kind and courteous as well as knowledgeable and efficient. Very pleased!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and courteous

Very pleased with service and Jake, who was exceptional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Comfort Experts Service!

Justin has been the latest in the long line of high quality representatives from Comfort Experts who’ve come to service or repair our AC unit. The scheduling has been consistent and reliable, as have the friendly technicians who’ve come for routine or emergency service calls.

  • Overall Experience
  • Quality
  • Price
  • Convenience

The Technician was excellent!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Alex was professional and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Kellen was very knowledgeable and honest!

  • Overall Experience
  • Quality
  • Price
  • Convenience

So professional and well mannered!

So well-mannered and professional. Tyler understood what we requested and offered logical solutions.


Response from Comfort Experts Inc.:

We’re delighted to hear about your recent experience with us and we’re so pleased that you recommend our services. Thank you for taking the time to share your experience and we look forward to welcoming you back soon!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Excellent communication, professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Kellen is extremely professional and gave me a good explanation of the services.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for aledo, tx

Mark D.

Mark D. Job Checkin

Customer stated high humidity levels in home in home. Checked super heat subcool, checked airflow, checked temperature splits found txv bulb mounted incorrectly from another company. Removed and cleaned up pipe re installed correctly and insulated, found drain pan not under the 96% gas furnace and no drain protection for AC installed drain switch on primary drain and relocated drain pan under furnace. Comfort advisor coming out Monday morning to perform heat load calculation on home to give some options to fix humidity either installing correct size system or installing a dehumidifier.


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

Voted customer 60k electric system


Kellen M.

Kellen M. Job Checkin

Returned to home for a 2lb charge of r410a quote from previous visit. Before and after photos taken showing: R410a tank weighed on a zeroed scale, tank weight at 206oz and ending in 175oz, subcooling before and after 2lbs charge from 5° to 12.4° which manufacturers data tag states 13°. Successful charge. System cooling and functional at this time.


Justin  P.

Justin P. Job Checkin

2020 Goodman Gas Furnace Checked and tightened all electrical connections Changed Customer provided filter, filter is too small needs bigger size Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Supply plenum has slight biological growth build up 2020 Goodman Straight Cool Breaker at main panel was off upon arrival Checked and tightened all electrical connections Dual run capacitor is weak 45/5 reading 22/4.7 Primary electrical unit was acceptable Refrigerant levels are slightly low at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Uv system for biological growth inside system, Dual run cap, compressor saver and HBPPlan Installed compressor saver and auxiliary motor starter


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Performed plumbing tune up. Plumbing is in working order at this time. Three water heaters are over 10yrs old and should be replaced. Also recommend replacing multitude stops at toilets and sinks


Kellen M.

Kellen M. Job Checkin

Had a phone call with Gross and he verbally agreed to purchase 2lbs of r410a refrigerant 4/24/25. I informed dispatch to put it on me first call on 4/24/25. Claimed he purchased a home warranty today and will deal with the major issues at a later date with them.


Justin  P.

Justin P. Job Checkin

2017 Bryant Gas Furnace Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Emergency drain pan has rust build up Blower motor and wheel have slight dust build up Evaporator coil has slight build up 2017 Bryant Straight Cool Checked and tightened all electrical connections Dual run capacitor was weak Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended UV system for biological growth on coil, drain safety, Dual run cap and compressor saver Replaced dual run cap


Alex  D.

Alex D. Job Checkin

Install 48k heat pump horizontal keep current filtration includes code kit


Kellen M.

Kellen M. Job Checkin

2017 5t electric. 2006 upstairs unit, r22 leaks in coil detected. Filter replaced. Drain line clear. Uv bulb out. Biological growth present. Compressor inrush amperage exceeds manufacturers specifications. Refrigerant charge acceptable. Low voltage wire unprotected. Contactor has heavy pitting and scorching. Homeowner declined all recommendations for optimal performance. Homeowner declined my invitation to inspect 2006 upstairs unit, but i still did a courtesy leak detection. Encouraged him on the upstairs unit but is not ready.


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

Upon arrival tech replaced the old x13 motor with the new one tech highly recommends a cleaning for the blower cage . System is up and runing


Jose  G.

Jose G. Job Checkin

Adjusted the indoor settings for electric heat.


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

Upon arrival, technician found that condenser was coming on downstairs fan was not working properly. Module inside fan motor is out. Order a near fan motor.


Justin  P.

Justin P. Job Checkin

Airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Blower wires have biological growth build up Evaporator coil has slight biological growth build up Straight electric Condenser Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv system for biological growth, anti microbial pan treatment, sealing all air leaks, coil cleaning and compressor saver Customer signed up for HBPPlan


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

House built in 2022 First unit to the left is for up stairs. Gas system Lenox system Coil M/N CHX35-30B-6F-2 S/N 6021K18032 evaporator coil is up to techs standards tech didn't find a leak A-frame coil does have signs of rust which is common for the age of system Coil is using a thermal expansion valve "TXV" There is no drain protection on system No biological growth at this time Furnace M/N ML180UH070E36B-55 S/N 1721M26514 Blower motor bearing are in good condition Blower cage doesn't need a cleaning Inducer motor is in good condition Gas line has sediment trap Safetys are working properly Heat exchanger is up to standards and has no cracks Filter is still clean Both return & supply plenum are metal inside and are in great condition Flue pipe is up to code Sub cool is at 8 & super heat is 20 Lennox M/N ML14XC1S030-230A05 S/N 1921K66769 Compressor has a inrush amp of 79 manufactur recommendations 67.3 Running amps on compressor is 4.59 under manufactur recommendations F


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Performed plumbing tune up. Toilet in guest bath fills slow. Gave recommendations for repairs. Customer declined repairs at this time as home is under renovation. Could not look at master bath as flooring is being redone