Hunter did an excellent job servicing my my air conditioning unit. He was polite and very thorough.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Hunter and Zachary were both very professional and personable. I appreciated how they honestly explained an issue I had but were not pushy about telling me I needed a part replaced (which I gladly did after getting a detailed explanation). If all of your technicians are like them, you clearly have a great company. This is the first time I used your company and will continue to do so in large part to these two outstanding gentlemen.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Great Technician with excellent feedback and explanation.on the system
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Replaced compressor,pressure tested and pulled vacuum changed txv. Charged system to 8 degree subcool. Left with system in cool
Super tune up performed today on a Lennox heat pump with air handler installed in 2020. All electrical connections are tight with no corrosion. Existing UV system was not working and had previously been dismantled. Installed a new UV 200 germicidal system. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Compressor saver was installed in the outdoor unit. Performed a free courtesy check in the upstairs unit. R22 straight electric system installed in 2003. System is low in refrigerant and the system should be replaced. Main system running and cooling the home upon departure.
Super tune up performed today. There is a restriction in the outdoor unit metering device that is causing the system to shut down on high pressure in under a minute. Metering device and filter line drier need to be replaced. Heat pump will not work as it is currently. System will only heat home with he emergency heat strips. All electrical connections are tight with no corrosion. Heat strips are pulling proper amperage. Evaporator coil is dirty and needs to be cleaned. In cooling, the compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Customer declined repairs at this time.
Upon arrival indoor was blowing Heatpump was not functional. During evaluation found board to be throwing low pressure cutoff code. Attached gauges and system was completely flat. Added some refrigerant to system to perform a leak search. Upon adding refrigerant the condenser coil began to hiss indicating a big leak in the condenser coil. Located leak on corner where dog has been urinating. Dog urine is acidic and ate through the aluminum coil causing leak. No longer under warranty due to that fact. Customer firmly stated he's getting a second opinion for the condenser coil that is leaking due to customers dog urinating on system.
Grounded compressor on upstairs system. System is lifetime P&L Did not collect due to uncertainty of parts being found NEED TO ORDER COMPRESSOR AND TXV MODEL - ASZ160241AC SERIAL - 0810201091
Two system super tune up performed today. All electrical connections are tight with no corrosion. Both blower motors are working properly. Systems are clean. Heat exchangers, gas valves and burners are all working accordingly. Outdoor units were washed and waxed. The expansion valve on the smaller bedroom unit is failing. Bulb is not sensing temperatures and valve is not opening and closing as it should. Highly suggest replacing. Neither unit had drain protection n suggest adding a drain safety switch to each unit to prevent water damage in the home.
Performed Tune up on both systems today Checked all components of the furnaces and changed filters. All components working properly. Both UV systems are no longer functioning, talked with customer about more robust and efficient UV upgrades. Checked all Heatpump components and washed condenser coils from the inside out. Recommended UV system upgrades
Came to job to hang chandelier and look at lights and closet
2017 Colman Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain has build up in trap Blower motor and wheel were acceptable Evaporator coil was acceptable Blower wires have biological growth 2017 Coleman Heatpump Checked and tightened all electrical connections Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended UV systems, anti microbial pan treatment
Two system cooling tune up performed today. All amp draws are within spec. Refrigerant levels are acceptable. All outdoor units were washed and waxed. Blower wheel on downstairs unit is dirty and needs to be cleaned. Biological growth is present inside of the downstairs air handler. Suggest cleaning the blower wheel and adding a germicidal light.
I have spoken with the customer about estimates on a generator inlet and replacing a bunch of his switches with smart switches he needs to talk with Dawn first before he makes any decisions on the things that we talked about
9/8/25 Reschedule to come back out on Tuesday the 16th in the evening around 6pm with an additional hand to level the air handler.
Upon arrival tech h found that the emergency drain pan had fallen. Tech reinstall pan tech found that primary drain was clogged tech uncloged drain
Level 2 36k, level 3 36k 28,835