Found defrost control board is failing to turn off condenser fan motor upon a defrost cycle will be pausing call and waiting for parts Left unit on in emergency heat
On this job I found the condensor trip on high pressure cut out. Could not get system to generate hp. I removed 2oz of freon. The system is working as it should.
Install 48k heat pump package unit keep current filtration includes code kit
Quoted a level 2 48k heat pump package unit for $15,039
Arrived at customers house for heat tune up All components working to manufacture spec Recommended pan strip anti microbial mist and IAQ200 for biological growth it is all over the unit All declined
On this job I inspected a propane furnace. The system doesn't seem to have any cracks around combustion chamber flame sensor and ignitor are in tolerance. He is interested in propane generator and a new furnace.
Today I performed a warranty heating tune-up checked everything indoor and out wash the coils everything is running and functioning as it should and customer has just about every Improvement accessory available only recommendation was a drain switch but the customer keeps up with white vinegar down the drain line once a month and decided against it no issues found no repairs made
8/5/24 Will need to return to install new supply grilles for the living and dining area. Customer would like us back out on the 26th of August. The two grilles in question are to it 10x10x9 supply boots. 8-29-24 Installed two 10x10 supply registers.
For this job we installed an IAQ 200, installed a pan strip in the coil drain pan, and cleaned the customers blower wheel.
For this cooling tune up I inspected the air handler and condenser. Inside the condenser the blower motor was pretty dirty with Bio growth inside it and on the wiring. At the condenser the capacitor was out of tolerance, and there is no compressor saver installed. Refrigerant levels were within range. I recommended a compressor saver and replacing the capacitor.