Very efficient and tidy. They explained things thoroughly and answered all our questions!!!!
THANK YOU FOR YOUR ATTENTION AND PERSONAL ATTITUDE TOWARD ALL ISSUES THAT ARISE.
Marshal was polite etc and answered a few questions fo me.
This is the first time I was able to get any website of yours on my system. 100% of time, I have been very very pleased with the service and the respect that your employees give me.
i have been very pleased with the service and the respect all the repair man have showed me.
Got straight to the task at hand.
Response from Comfort Experts Inc.:
Thank you for your review
For this job, I performed a super tuneup. During the tuneup noted that the LRA was right at maximum capacity. Recommended either soft stad or a hard start kit for longevity of the system. Owner opted to have hard start kit installed. Brought down initial amp draw from 107 to 77.6. No further recommendations were made. Thank you for choosing Comfort Experts.
Guaranteed call - unable to reach customer
For this evaluation the customer stated her system was only cooling even when set to heat and with the temperature set to 78⁰. Then randomly the system stopped responding at all. I turned the thermostat off and manually jumped the system to bypass the thermostat however the reversing valve had constant voltage, even with a call for heat so it is only cooling. This indicated the thermostat is the culprit and sending a constant call for cool. I replaced the thermostat under warranty with a new one and the system started working like it should.
Arrived at customers house for super tuneup All components working to manufacture spec Recommended anti microbial mist for biogrowth Home owner installed board to cover light fixture but didn't secure with nails Board broke underneath when stepped on and foot went through ceiling Owner understands that isn't on the company and signed form stating such
For this evaluation the condenser was showing an L2 Fault "HPCO Lockout". I reset the board and gauged up where the high side pressure was only getting to around 350 PSI and holding steady, not close enough or over to trip High Pressure cut off. I ran the twice and both times the system reach temperature with the same result not hitting head pressure. I disconnected the high pressure cut off switch on the board and use the jumper to close that circuit and bypass the high pressure cut off switch.
Found defrost control board is failing to turn off condenser fan motor upon a defrost cycle will be pausing call and waiting for parts Left unit on in emergency heat
On this job I found the condensor trip on high pressure cut out. Could not get system to generate hp. I removed 2oz of freon. The system is working as it should.
Install 48k heat pump package unit keep current filtration includes code kit
Quoted a level 2 48k heat pump package unit for $15,039
Arrived at customers house for heat tune up All components working to manufacture spec Recommended pan strip anti microbial mist and IAQ200 for biological growth it is all over the unit All declined
On this job I inspected a propane furnace. The system doesn't seem to have any cracks around combustion chamber flame sensor and ignitor are in tolerance. He is interested in propane generator and a new furnace.
Today I performed a warranty heating tune-up checked everything indoor and out wash the coils everything is running and functioning as it should and customer has just about every Improvement accessory available only recommendation was a drain switch but the customer keeps up with white vinegar down the drain line once a month and decided against it no issues found no repairs made