1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for the colony, tx

Rated 5.0 out of 5 stars based on 13 customer reviews

Excellent

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

They were great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Survey

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

As always great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Very efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always taken care of

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional Service

Technician did an excellent job 👏

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for the colony, tx

colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival system was running and cooling. Found good air flow from supply ducts on master bedroom system, recommended a water safety and an advanced leak search later in the summer/fall.


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival system was running and cooling producing an 18 degree delta. Outdoor units dual run capicator was out of tolerance. Recommended replacing this and adding a compressor saver kit to increase the life of the capicator and compressor. Raining during visit.


Robert V.

Robert V. Job Checkin

Duct cleaning completed


Mike R.

Mike R. Job Checkin

On this job I inspected the cooling side of the system. The freon levels are on point. I changed the filter and washed the condensor. The system could benefit from duct cleaning.


Alec G.

Alec G. Job Checkin

Upon arrival system was off Turned system back on and had good refrigerant levels,cap was within tolerance and coils were clean Delta T was a 12 Spoke to customer and let him know system is cooling but to keep an eye on it and give us a call back if he sees anything else


Alec G.

Alec G. Job Checkin

Upon inspection discovered that cap was below tolerance and was not allowing the compressor to turn on Replaced cap and was supplying 56 degrees out of the vents


Lisa M.

Lisa M. Job Checkin


garrett.young@acgenius.com

garrett.young@acgenius.com Job Checkin

For the super tune-up I inspected the furnace and condenser. For the most part everything was measuring with a manufacturer specs and running well, however the blower capacitor was out of tolerance by more than 5%, so I recommend replacing that before it fails. Additionally one of the blower Wheels was pretty dirty, making the blower work harder and putting more stress on it. I recommend replacing that blower capacitor, cleaning the blower wheel, a compressor saver for the condenser, as well as a UV system to kill biological growth and any other pathogens.


Mike  S.

Mike S. Job Checkin

Tested all components all measured within ratings and specs. Refrigerant level is normal. Washed and cleaned condenser. Changed filter. Recommend duct cleaning lvl1


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival systems were running and cooling producing 18+ degree deltas. Indoor units had clean coils and drain lines but dirty blowers. Supply plenum for upstairs system had large spots of biological growth. Outdoor units passed all electrical testing but were overamping on start up. I recommended compressor saver kits to address this and to reduce wear and tear on the compressor. I recommended an April aire upgrade kit to prevent further dust bypass and I recommended iaq 200 uv systems to prevent further biological growth and improve air quality.


Daniel S.

Daniel S. Job Checkin

Arrived for STU Recommend refurbishing, IAQ 3000, blower clean and coil clean. Customer would like to have a comfort advisor out on May 2/2024 @12-3


Mike  S.

Mike S. Job Checkin

Tested all components all measured within ratings and specs. Refrigerant level is normal. Washed and cleaned condenser. Customer changes filter himself on the 1st every month.


Brock S.

Brock S. Job Checkin

Arrived for Eval of upstairs system. Asked home owners if they wanted their down stairs to be looked at and they said yes. All components were working and in tolerance Recommended IAQ 200, 1000, Blower clean, Coil clean, panstrip for both units. Surge protection for whole house and membership. Relayed Information to customer and told them that their upstairs system was working. Customer wanted to think about recommendations.


Blake  B.

Blake B. Job Checkin

Tech arrived at a tune-up/ IAQ estimate. Upon inspection, the capacitor was out of tolerance. The condenser coils were hosed off to assist with air flow across the coils. The refrigerant was within range. The filter was dirty. The blower area was dirty and there was growth present in the system. There was ductwork that was not sealed properly in the attic. Tape was applied to these areas. The Delta was within range. The customer was informed of recommendations today. He is interested in the IAQ 1000 Filter, 200 UVC System / Air Cleaner and Level 2 Duct Cleaning. He will speak with his wife and will call us back. He would like a follow up next week if we haven't heard from him by then. The system was functioning upon departure.


Blake  B.

Blake B. Job Checkin

Tech arrived at a complimentary tuneup. Upon inspection, the capacitor was out of tolerance. The condenser coils were hosed off to assist with air flow across the coils. The refrigerant appeared to be overcharged and the TXV was not functioning. The blower area was dirty. The customer was provided with duct cleaning estimates upon request. The customer was informed of recommendations today. He will speak with his wife and will call back in. The tech will follow up at a later date. The system was functioning upon departure.