Very friendly and knowledgable. Came right out same day. Thank you!
Easy schedule and technician was prompt, did a great job and explained what he did
Prices for work is high. They try to up sell for things every time they come out. I know they have to make more and more money to stay in business, but it gets a little irritating.
Response from Comfort Experts Inc.:
Thanks for the glowing review!
Ryan did a great job! Helped us get ahead of some minor issues we were having. Changed the filter in the attic. He was fast and friendly and knowledgeable! Will use them again in the future!
The AC tech was knowledgeable, and did inform me of what needed to be done. I learned what might be done with my system to improve it, which is nice. But not for $108. The fan was dirty, so Im going to clean it. The capacitor is failing, so Im going to replace it. One of the drains was dangling, so Im going to tie it up. There are exposed low voltage lines that are exposed, that I will cover up. I guess I expected a slight tune up, but there wasn't really anything done to the system other than advice. I do appreciate it, but I most likely would not pay for the service again, based on cost.
This is a 2700sq ft house cooled and heated by 7 9000btu mini split 2 have cracked face plates and make loud sound when blower kicks on. This is due to dust build up around the blower wheel. I recommend replacing this with 5ton heat pump system for the whole house. Or replacing the to mini split system that have issues.
2019 Amana gas furnace Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Ignition system is functional All safeties are functional Blower Blower motor and wheel were acceptable Evaporator coil was acceptable Uv system is functional
Arrived for CTU Filter fine Drains clear Delta is good Blower and coil slightly dusty Washed Condenser coil Motors capacitors and refrigerant fine Moved soft start kit to underneath the electrical cabinet to prevent water damage
This is a an elder couple thinking something was wrong with the system. After checking filter freon amp draws and caps everything checked out fine. System is less then 2 years old. It could use easy start and uv system but didn't qualify for financing.
I quoted a le1 48k straight cool horizontal for $9736 Customer wants another quote then decide on repairing or replacement
Arrived to no cool. Customer states that the system is freezing up. Evaporator coil and blower wheel are both very dirty and causing very poor air flow. Customer is upset that the previous technician sold him a soft start for the outdoor condenser without addressing the air flow issue. Coil is very corroded as well. Customer would like to speak with a comfort advisor to get an estimate for a new system before deciding whether to fix this 14 year old straight electric system or replace it.
8/17/27 This system had a out of tolerance compressor cap. Reading 40 should be 45. Today I replaced it under warranty. I returned today and install iaq200. I could not install the easy start because I do not have the correct size. I need / icm easy start 16A. Pausing call again until I receive icm easy start 16a
Today I cleaned the system condensor take the top off and cleaning it from the inside out. I removed this cooling tune up fee because they did a memebership and an easy start system today. I installed the easy start and inrush is 27amps when it was 104. System has 10° of subcooling and currently uses a piston. The evap coil is dirty but has caused any issue so far. I recommend replacing the coil of cleaning it.
This system had a out of tolerance compressor cap. Reading 40 should be 45. Today I replaced it under warrenty.
2018 1.5t hp attic horizontal. Verified - no manufacturers warranty, was only a 5 year. Homeowner claims it's not keeping up with the demand. History of refrigerant recharge and capacitor replacement by other companies. His father used us at another property when he was alive. Blower wheel is dirty. 1inch filters have been replaced. Drain line clear. Due to conversation, I performed a courtesy leak detection while homeowner was with me and detected refrigerant molecules at the evaporator coil. Washed outside unit and put guages on to check refrigerant charge. Confirmed low leves and put almost a pound in until my levels were within manufacturers specifications. Expressed to Homeowner the options being outside of a manufacturers warranty and the issues present. Homeowner is interested in a package unit if possible. Location of indoor unit is against code for proper access. 13oz r410a was purchased, I educated on the pros and cons of doing so. CA appointment 8/6/24 5pm to di
Dual run capicator reading 0/0 on arrival, once replaced system ran with no issues.
Arrived for eval Customer stated the system would come on and off Ran test and found out the system was throwing a lock rotor code The compressor saver went out Recommend new compressor saver with warranty Customer wants to wait Compressor did not come on