Rated 4.8 out of 5 stars based on 6 customer reviews

Excellent service

He was very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

They do a good job.

Prices for work is high. They try to up sell for things every time they come out. I know they have to make more and more money to stay in business, but it gets a little irritating.


Response from Comfort Experts Inc.:

Thanks for the glowing review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Ryan did a great job! Helped us get ahead of some minor issues we were having. Changed the filter in the attic. He was fast and friendly and knowledgeable! Will use them again in the future!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

..

The AC tech was knowledgeable, and did inform me of what needed to be done. I learned what might be done with my system to improve it, which is nice. But not for $108. The fan was dirty, so Im going to clean it. The capacitor is failing, so Im going to replace it. One of the drains was dangling, so Im going to tie it up. There are exposed low voltage lines that are exposed, that I will cover up. I guess I expected a slight tune up, but there wasn't really anything done to the system other than advice. I do appreciate it, but I most likely would not pay for the service again, based on cost.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Fast Response Time

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lakeside, tx

mark.grant@acgenius.com

mark.grant@acgenius.com Job Checkin

Tech Cody and Mark arrived to customer's home and met Mr. Phil. He showed us inside to the thermostat and the access to the indoor unit. We started inside with replacing the filter and inspecting the blower wheel. The blower had minimal dust buildup and all the electrical control was in good condition. The evaporator coil was clean and the temperature delta T was 18 degrees. I poured a gallon of water into the drain and it went through with no issue. The unit had an IAQ 200 and both bulbs were not in need of replacement. Next we headed outside to the condenser coil, the electrical equipment was operating normally according to the data tag and the wiring was in good condition. We cleaned the leaves from the bottom and washed the coil out. We hooked up the guages and found the charge of the system to be good. The unit had a compressor saver installed.


Tyler S.

Tyler S. Job Checkin

04/19/24 Tyler s- basic check up. Waterheater is 18 years old and needs to be replaced soon. Customer will hold off atm


Autumn L.

Autumn L. Job Checkin


Derek.bryant@acgenius.com

Derek.bryant@acgenius.com Job Checkin

Mark to return when have proper vent parts


Ian C.

Ian C. Job Checkin

I Located issue and performed temporary fix, whip from outlet to furnace has no ground, control board sending fault code for bad ground The temporary fix is is not the correct fix, new circuit for ground needs to be run Flue pipe is not up to code and is not performing correctly, going to eventually ruin the furnace, or allow combustion air leak.


Mark W.

Mark W. Job Checkin

Move washer and dryer and waterheater Cut floor and moved water lines and drains will have to return tomorrow to finish water lines and gas line


Mark W.

Mark W. Job Checkin

.


mark.grant@acgenius.com

mark.grant@acgenius.com Job Checkin

2021 Daikin airhandler Checked and tightened all electrical connections Changed customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Heat strips were functional and within manufacture range 2021 Daikin Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Cleared debris from bottom of unit Waxed top of unit Recommended compressor saver and condensate pan treatment


Derek.bryant@acgenius.com

Derek.bryant@acgenius.com Job Checkin

3/13/24 Reschedule with Mark W & Derek B to come out Thursday morning the 14th


Brock S.

Brock S. Job Checkin

Tech Cody arrived to customers home. I went to the indoor closet furnace and did a diagnostic of system startup. All the safeties functioned as they should and furnace started up with no issue at all. Inducer fan motor pulling point three amps was below the manufacturer specifications. Customer had air scrubber and UV light installed on system. I replaced the filter for the customer. Once I took a look into the attic and saw the insulation I noticed that it was very low and I notified the homeowner that they need to be getting some insulation soon.


Mike R.

Mike R. Job Checkin

I came back today to install the uv system.


Mike R.

Mike R. Job Checkin

On this job I'm coming back on wednesday between 10 and 12 to install a germ light in the return. The system is 3 years old and has no issues.


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

I arrived and replaced the capicator on the left side of the houses outdoor unit. Customer did not answer door. Unit was running and heating when I left.


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival both systems were running and heating producing 20 degree deltas. The indoor units had clean blowers and coils and the drain lines flowed when flushed. Both outdoor units had weak capicators and one outdoor unit was overamping on start up. I added a capicator and compressor saver kit but need to return to add the other capicator. Please schedule me to return Thursday with the capicator.


Justin  P.

Justin P. Job Checkin

2011 Trane gas furnace Checked and tightened all electrical connections Customer recently changed filter Drain was clear and draining poured a gallon of water down Blower motor and wheel were acceptable Evaporator coil was acceptable Ignition system was functional All safeties are functional 2011 Trane Straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Customer stated there were 2 rooms that don't keep temperature as she would like. looked at insulation in attic, insulation above the 2 rooms and in other areas of attic were very bare could see drywall in multiple spots. Talked with customer about adding insulation to attic. Customer stated she will do research.