Annual maintenance checkout of a/c performed nicely by Colby. He's a quick and efficient professional. Thank Colby!
Danny was great! Addressed our concerns and very knowledgeable. Thanks Danny!
Adam did an excellent job for us, he is excellent at his craft. J excellent is great at explaining why something needed replacement etc. In the future, I would want Adam To service our needed services!😀
Since getting the new system i have had a constant cough and so has my roommate… the place was left dirty and my rug was damaged, as well as my attic ladder…
next time would like a better time table on arrival , lucky i was able to have somebody there when he did show up
Mike gave me great recommendations on how to keep house cooler.
Although we’ve had several issues with this unit we have still received decent service from techs, office staff etc. Good thing we have a warranty or it would be very expensive.
On arrival system running and cooling producing 17 degrees delta. Indoor unit dusty with beginning signs of bacterial growth in supply plenum. No water safety's on machine. Outdoor units dual run capicator is out of tolerance. Outdoor unit otherwise passed all electrical testing. Customer planning on having friend replace capicator.
Replaced value germicidal system with IAQ200 Sealed return plenum Relifted and mounted return duct System cooling at exit
On arrival system running and cooling producing 18 degree delta. Indoor unit passed all electrical testing. Drain lines flowed when flushed. Uv bulb out of tolerance and burnt out. Outdoor unit passed all electrical testing. System cooling as I left. Scheduled air quality visit for later today.
As far as I can tell the system is not making any noises beyond what is normal. The return has small hum noise. I watched and monitored it for 30 min and didn't catch anything abnormal happening.
Customer already had job completed and double booked us
For this job I initially showed up for an evaluation however the customer went ahead and took care of the problem which happened to be the primary drain line going into the hub drain was clogged. So instead I did a cooling tune up since the customers are entitled to two per year. All in all everything looks good however with the customers permission I went ahead and installed a clean out for the primary drain line and a condensation water treatment strip.
for this job, we did an evaluation. At arrival the system was on but not running. Homeowner said that the system had just gone off the other night and turned on momentarily before turning off again. I started at the air handler and checked the drain lines noticed that the safety had been activated and the lines were clogged. Homeowner accepted a drain clearing and a membership. After clearing the drain, we put everything back together, turned the thermostat on, and waited 20 minutes to verify that the unit would continuously run.
Estimate to install ceiling fan. Emailed to customer. He has some other quote coming in and will reach out if work is needed.
Panel looks great as well as the sub no surge protector and currently not interested but gfci's are present and functioning
Arrived onsite inspected are drain where ac drains into pipe. There is no moisture there now and is draining properly. Advised customer if the problem happens again may need to run a camera and see if something else is going on under home.
On arrival system running and cooling as intended and drain lines flowed when flushed. Outdoor units capicator was out of tolerance and compressor was overamping on start up. Added compressor saver kit and changed out customer supplied thermostat. System cooling as I left. Raining at time of maintenance.
Install 36k gas downflow keep current filtration includes code kit
Sold 36k level 2 gas downflow unit 13, 638
Came to house to give quote to aff 80 amp car charger
For this job , I did a super tune up. Everything in the airhandler looked Suggested he get a new filter box and and also showed him the biogrowth and suggested a UV system. At the condenser, SupEr heat and sub cool were in range. In rush was high and capacitor was out of tolerance. Suggested a new capacitor and he installed a hard or soft start. Was told he needs to speak with spouse first. Washed condenser and put everything back together. Air conditioning was running when I left