Mike gave me great recommendations on how to keep house cooler.
Although we’ve had several issues with this unit we have still received decent service from techs, office staff etc. Good thing we have a warranty or it would be very expensive.
Good to work with; dependable and quite knowledgeable.
Very thorough and explained every detail. Would love for him to be our regular service tech
He was very professional. Completely confident.
I called next day requesting receipt. Received apology, & promise to send it. 2days No receipt. ????
Free hot water tank clean. Unable to complete no water draining.
Arrived for rec work Ininstalled bad condenser and reinstall new one Nitrogen tested and vacuum Pumped back up and system running before I left
He wants to see CA to talk about mini split system for game room. Also would like to add 1 run of duct to office space. He will call us when he is ready
Arrived at eval System not running and the system kept on flipping the breaker Ran test and found out it’s the compressor Urgent order request by customer
Returned and flipped breaker on east side unit. System on and functioning when I left.
His panel looked good he just needs a surge protector but he has gfci's and the plugs tested well as well as his solar set up, the conduit to his meter base does have a little bit of space that needs to be filled
Arrived for STU Filter fine Drains chat Blower and coil dusty Flame sensor corroded Washed Condenser coil Capacitor in tolerance Fan motor over heating and likely to fail this summer Hard start kit recommended to bring starting amp draw into factory spec
Arrived and reset east side system as recommended.
Arrived to system leaking water Found main drain clogged Repaired drain line Took apart condensor and washed down outside coil All components are in tolerance Recommended pan strip and recommended plumber Plumbing line has small-medium build up System left on cool at exit
Arrived for system evaluation System compressor reaches over 24 amps vs manufacturer 18 Imediate heat build up and increase in pressure All components are in tolerance for system Compressor unable to fully run Recommended appointment with comfort advisor Homeowner will call back to schedule appointment System disconnect left out and system Fan on only
Arrived for eval Called Brett and he had us turn off the east unit and back on. Waited and the system came on. Lady at givemethevin denied signatures
Performed inspection for plumbing on home. Made some recommendations to customer. She said will get done when she is ready paying for hail damage o. Her vehicle at the moment.
Zak L. completed annual hvac tuneup.
Arrived for AHC Filter fine Drains clear Blower and coil slightly dusty - filtration upgrade recommended Furnace components are fine Condenser coil clean C capacitors, Motors, refrigerant levels fine