Hunter is the best, very communicative with the customer and thorough with his job.
Very courteous, explained things very well both visually and verbally. Made sure all that was explained was understood. Extremely patient.
Mark has been here several times. He is pleasant and skillful in diagnosing and doing the service.
Mark Dennison took his time to check all of the A/C unit. Very friendly and knowledgeable technician. Really appreciate his work and attitude.
Mark is very thorough and pleasant. Explains everything well.
Ian was upfront on the cost and did a great job replacing toilet.
Derek was able to fix the problem with excellent results. Enjoyed his company also.
The men were patient and explained everything go on. They were here on time and very professional.
Upon arrival techtbtalked to home owner to see what was going on tech found Is that two other companies have been out and given estimates for float switch tech talked to homeowner and installed float switch tech made sure system was running properly before leaving
Upon arrival tech removed the old supply plinam and installed the new one the unit is runing
Upon arrival tech started with the air handler tech found that the insulation inside the supply plenum is falling apart tech recommends replacing the plenum tech headed out side where tech found everything to be working properly and up to standards. The home owner is going through financing Tech will need to return once metal plenum comes in to install it properly. Air handler dimension 24" × 12"× 4FT
Customer interested in filtration/softener and possible ro system at kitchen sink. Need to get info/ literature and follow up with customer. Customer did not want inspection
Fully functional. Happy homeowner. Answered all questions, insulated the primary condensate line per code and adjusted door of condenser unit to seat properly. Will talk to install about the possibility of adding rubber gromets to the bolts on the frame to the brick. Low voltage is not protected.
Install 60k hz inverter heat pump with ultra high efficiency filtration with uv system, code kit and duct cleaning
Came to job for complimentary inspection and guy had a few things he wanted quotes on and gave him those quotes and also talked about adding a generator plug And was very interested in that and will probably call us back in the future.Just has the big system being put in same day and just needs sometime before he does it
2011 5t hp attic horizontal. Expired manufacturers warranty. Drain line has rust sediment buildup. Filters are replaced appropriately. Ducting has energy leaking at supply plenum connections and down stream. Indoor unit has heavy biological growth buildup. UV light system not functional. Biological growth found on Electric heatstrips. Evaporator coil has visual oil streaks, courtesy leak detection discovered refrigerant molecules present. History of capacitor replacement. Inrush amperage is still high, almost 100amps on startup. Diminished due to a compressor saver. Refrigerant charge is below manufacturers specifications. Contactor is buzzing. Shared with homeowner all photos and video evidences, educated on system performance and saftey. We discussed all options including repair vs replacement. Homeowner agreed due to age and parts availability to a CA appointment 3/29/25 at 10am. System functioning but diminishing in performance. Electrical inspection set for 3/31/25. Plu
X13 blower motor replaced under warranty. Performed function check. System running and cooling the home upon departure.
Bedroom unit is an Amana air handler with heat pump installed in 2020. All electrical connections are tight with no corrosion. Some slight buildups starting to form on the blower wheel and the evaporator coil. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. 35/5 dual run capacitor was changed under warranty on this visit. Outdoor unit was washed and waxed. Main unit is a Coleman heat pump with air handler installed in 2016. X13 blower motor is not working properly. It is turning on and shutting down after about 10 seconds on run time. Motor is getting hot and shutting down on a limit switch. Motor needs to be replaced under P&L warranty. Outdoor unit was washed and waxed.
2019 Amana Airhandler Checked and tightened all electrical connections Filter was acceptable Drain was clear and draining UV system is functional, UV lamp needs replacement Heatstrips were functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable 2019 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv lamp replacement or upgrade
Unstoppable main line flush to ensure stoppage clear job complete
Upon arrival Customer stated system was blowing cold air when system is set to heat. During evaluation found that the heatpump was tripped on high pressure. Found that the filter was heavily compacted with dust causing pressure to rise when running. Removed filter and pressure normalized. Recommended replacement of filter as soon as possible
Heating tune-up completed during inspection I found that the customers UV light was no longer operational, recommended replacement of the UV bulb due to them only lasting 2 years customer agreed bulb swapped. System is operating efficiently all all electrical components are operating properly and safely, electrical connections tight and secure throughout. Refrigerant levels acceptable airflow acceptable During my visit customer expressed a couple of concerns to me One of them being one room had seemed to be be colder or hotter than the rest of the house, when inspecting duct and vent I found that the event for this room was actually just blowing into the hallway, flipped vent around for customer to see if this will change anything room has a giant window and does have a small difference in temperature. Cuz we're also explained to me that they are not happy with the dust levels in the home seem to have a lot of build up, my recommendation for fixing this is a air cleaner upgrade which