Great service and professionalism. I didn’t feel pressured to make a decision or to lean one way or the other.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Mark was great. Excellent service, very thorough. Would highly recommend!
Overall Experience
Quality
Price
Convenience
Justin was knowledgeable and answered all of my questions.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Adam was very informative. He answered all my questions gave me a price on a new unit and I just can't see spending that much money for a water filter but thanks for sending him out
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Joe and Angel were thorough in the install, answered all my questions, and addressed all my concerns. Toby was a great source of information, and his customer/communication skills were a huge factor in sealing the deal.
Overall Experience
Quality
Price
Convenience
Great service! Ian was very knowledgeable and knew right away what our issue would be. He was correct, and got repairs in place quickly. Service took less than 45 minutes!
Overall Experience
Quality
Price
Convenience
Mark is a professional who knows his work and doesn’t mind explaining what we don’t understand
Overall Experience
Quality
Price
Convenience
Very helpful and knowledgeable on looking at our unit at 10pm on a Monday!!
Overall Experience
Quality
Price
Convenience
1/28/26 Techs to return with Mark W Friday after meeting 1/30/26 Technician found that the thermal limit switch is the cause for two heat strips not to turn on technician is ordering a new one Technician will collect payment when technician returns
Both breakers to air handler were overheating at the bus bar attachment. Replaced both Eaton breakers (60 amp x 2), relocated them in the panel, and system is functioning normally at this time. Buss bar has discoloration where breakers were attached. I recommend buss bar replacement or breaker panel replacement to ensure proper operation and safety.
Mark D. performed a thorough annual heating system check, cleaning filters, inspecting ductwork, and ensuring all components functioned properly. Safety and efficiency were prioritized throughout the maintenance.
Heating tune up performed today on a down flow air handler with heat pump installed in 2019. All electrical connections are tight with no corrosion. Blower motor is acceptable. Blower wheel and evaporator coil are clean. Mild corrosion is present on the evaporator coil. Compressor and condenser fan motor are working as they should. Reversing valve and defrost control board are acceptable. Heat strips are pulling proper amperage. Outdoor unit was washed and waxed.
1/2/26 Reworked estimate will have concrete removal crew demo first then begin rec work ...will return Monday second call for remainder of rec work Will return with Daniel Monday morning
Arrived to no heat on Daiken mini split 3 head system. System shutting down on low pressure. Found leak in evaporator coil in bedroom unit. Presented customer with estimates to repair.
Service performed today on four generac air cooled generators. Main house unit- air filter, spark plugs and oil and oil filter were changed. Checked valve clearance to find all within spec. Battery checks as good. Reset maintenance schedule and performed function check. System operating normally. Barn unit- air filter, spark plugs and oil and oil filter were changed. Checked valve clearance to find all within spec. Battery checks as good. Reset maintenance schedule and performed function check. System operating normally. Guest house/ lodging- two stand by generators at this location. air filter, spark plugs and oil and oil filter were changed. Checked valve clearance to find all within spec. Battery checks as good. Reset maintenance schedule and performed function check. System operating normally. All systems are performing normally at this time. All systems were cleaned externally and inside of the casings. All batteries check as good. Barn unit showed evidence of a possible
Her panels looked great she does not have surge protection but she's about to sell the house and would like to hold off, gfci's are present and in the correct locations the only issues she has are brown outs
Arrived to no heat. Found that the primary electrical control had failed and was not passing high voltage through the contacts. Replaced electrical control and added a compressor saver to help with the efficiency and reliability of the system upon start up. Performed function check. System running and heating the home upon departure.
Super tune up performed this evening. Two year old Trane heat pump with air handler. All electrical connections are tight with no corrosion. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Customer has signed up for the military appreciation membership.
Electrical to HVAC He's concerned with his compressor, says it keeps coming on without performing any function so no air is blowing and then shuts off again
2023 American Standard Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Blower motor and wheel were Evaporator coil was acceptable Condensate pan has slight biological growth build up Supply plenum was acceptable 2023 American Standard Straight Cool Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended UV system to keep Airhandler and air quality clean and compressor saver as compressor is over LRA limit. Signed up for HBPPLAN
2021 Lennox Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Blower motor and wheel were acceptable Evaporator coil was acceptable Heatstrips were functional and within manufacture range 2021 Lennox Heatpump Checked and tightened all electrical connections Dual Run cap is right at manufacture tolerance Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed top of the unit Recommended HBPPLAN, UV 300 or 200, dual run cap and compressor saver