1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for paradise, tx

Rated 5.0 out of 5 stars based on 10 customer reviews

Excellent service

Cody was very thorough and explained everything he did. He was very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Justin went above and beyond what was required of my service call! Very courteous, thorough, and explained everything he was going to do for repairs! Highly recommend

  • Overall Experience
  • Quality
  • Price
  • Convenience

AMAZING COMPANY

Our technician was amazing and diagnosed the problem promptly! Would HIGHLY recommend this company and all the people that work for them! EXCELLENT customer service!!!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Positive review

I wish one of the previous annual service folks would have told us about the part that would have been beneficial to our system. Cody was great though.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service?

Professional, courteous, good salesman, felt honest, and straightforward. We will specifically ask for Ian in the future.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Very professional, knowledgeable and helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very professional and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service.

Very satisfied

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for paradise, tx

nathaniel.burke@acgenius.com

nathaniel.burke@acgenius.com Job Checkin

Emailed estimate to install portable generator interlock outlet and kit. They are shopping around.


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

Upon techs arrival tech started with the air handler where tech did find that the evaporator and blower wheel are getting dirty tech found all electrical connections to be tight and and no corrosion on them at this time refrigerant levels are perfect at this time system is cooling properly at this time Tech left with thermostat set to 73 in cool mode


Ryan  M.

Ryan M. Job Checkin

For this job, the Customer would like an estimate to run new sewer lines from a new workshop being built to tie in to the existing septic system. Will work this estimate up with Mark and send over to customer Thursday morning 7-17-25


Alex  D.

Alex D. Job Checkin

Install 9k mini split


Don S.

Don S. Job Checkin

Ivivivi ub


Justin  P.

Justin P. Job Checkin

2010 Trane Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain was clear and draining Blower motor and wheel are HEAVILY compacted with dust, dirt and biological growth Evaporator coil is HEAVILY compacted with dust, dirt and biological growth 2010 Trane Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit has putting and carbon build up Refrigerant levels are off at this time due to the cleanliness of Airhandler Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from bottom of the unit Washed condenser coils from inside out Waxed top of the unit Recommended Level 2 duct cleaning, UV system for biological growth and clean air, compressor saver and primary electrical unit Talked with customer about Comfort Advisor visit, customer agreed to have comfort advisor appointment setup for 5/21/25 10-12 office confirmed


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

5/17/25 Capped service line off temporarily to give customers cold water to home will return tomorrow am and repair hot and cold quest to pee unions for permanent fix...please schedule for tomorrow am so I can collect material


Justin  P.

Justin P. Job Checkin

2018 Trane Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Uv system is functional, lamp is past replacement date Antimicrobial pan treatment is functional 2018 Tran Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Uv system upgrade and compressor saver


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

3/19/25 Technician took heat exchanger out, took it back to shop to clean, where techs were not able to clean it out completely. Mark W has ordered new heat exchanger, technician went back to put furnace back together, made it work for AC, furnace is down on heat side, technician will need to come back when new heat exchanger is in, tech confirmed AC side is working. Homeowner is aware furnace is down. MARK W ORDERED HEAT EXCHANGER WITH ROB


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

Technician found water and flu technician drain flu. Technician also found flames not going into heat exchanger technician has system down. Heat pump is working at this moment. Gas pressures are good. Flu is good corners are good. Everything is working properly except for the heat exchanger there is snoot in the heat exchanger technician recommends replacing heat exchanger to fix issue. Technician has emailed homeowner both estimates one with membership and one without. Whichever homeowner wants to go through LP gas valve needs to be ordered as well as heat exchanger needs to be ordered System is down at this moment


Mark D.

Mark D. Job Checkin

Super tune up performed today on a 5 year old Goodman heat pump with air handler. All electrical connections are tight with no corrosion. PSC blower motor and capacitor are acceptable. Heat strips are pulling proper amperage. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. All amp draws are acceptable. Outdoor unit was washed and waxed to protect it from sun damage. Thank you for choosing Comfort Experts.


Mark D.

Mark D. Job Checkin

System was slightly over charged when the evaporator coil was changed. Recovered 16oz of 410a refrigerant. System operating normally active of departure.


Mark D.

Mark D. Job Checkin

Evaporator coil changed out under P&L warranty. Pressure checked system, pulled a vacuum to 500 microns and recharged system. System operating in both heating and cooling upon departure.


Mark D.

Mark D. Job Checkin

Found system to be very low on refrigerant. Discovered a leak in the evaporator coil. Need to replace the evaporator coil and the TXV under P&L warranty. Need to order evaporator coil and TXV for Amana Model : AVPTC61D14 Serial : 2107567606


katie c.

katie c. Job Checkin