Cody was knowledgeable and professional. He was able to quickly service my unit and replace the UV bulb.
Ian was able to quickly find the problem and get the compressor working again.
I would definitely recommend them! Quick and friendly service. I called them about 7:30 pm Sunday and they were here the very next day Monday @ 10 am to fix my AC. Ian Conrad is definitely great at his job, and very professional. Thank you to hum, and their company. If I could I would give them 10 stars
Cody was efficient and pleasant and Explained everything he did and everything he found …. Enjoyable
Ian was very professional and explained everything as he went. He diagnosed and cleaned my unit without Hard selling me on anything new. I really appreciate his honesty and work ethic.
Good explanations using visuals, pleasant , good demeanor - pleasure to have in my home
Mark’s attention to detail and thorough explanations provided peace of mind.
Tyler was professional, honest & respectful. Appreciate Corin promptly correcting the scheduling mistake the original service scheduler made with my appt..
Appreciate Justin being on time, courteous & knowledgeable! He was efficient & informative. Plan to reschedule him for installation of a compressor saver, appreciate not being pressured to make that decision today, I would NOT have considered or trusted his suggestion had I been pressured!
Installed wwsp. Emailed estimates. New member. CUSTOMER WOULD LIKE TO HAVE AN HVAC TECH OUTTO DIGNOSE AC SYTEM NEXT WEEK MONDAY- WEDNESDAY. 5/5-5/7. PLEASE CONTACT CUSTOMER TO SCHEDULE APOINTMENT.
Super tune up performed today on a 5 year old Lennox straight electric system. 45/10 auxiliary motor start is showing as weak and is out of manufacture tolerance. This needs to be replaced. System does not have any drain protection. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Customer declined repairs at this time.
Replace frost free hydrant on back corner of home. Faucet broke in wall while removing. Was able to remove faucet without removing brick or drywall. Customer was not interested in membership at this time
Confirmed leak in the condenser coil. Because of the location of the leak replacement of condenser coil is highly suggested. Emailed estimate to the customer.
2024 Revolv Airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil has slight dust and biological growth build up 2024 Ducane Straight Cool Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Uv system, anti microbial pan treatment and compressor saver
Install 48k upflow heat pump keep current filtration includes code kit
Level 4 heat pump 48000 btu
Upon arrival tech bound capacitor blown technician also found low refrigerant Technician found lake and evaporated coil.Technician is having jimmy go out at 2
Super tune up performed today on a Coleman heat pump with air handler installed in 2017. All electrical connections are tight with no corrosion. X-13 blower motor is acceptable. Heat strips are pulling proper amperage. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed.
Upon arrival tech started at the airhandler tech found everything that everything was working perfectly fine tech did Recommend a pan strip to help with build up in summer time. Tech moved to the condenser where tech found that the compressor is having high inrush amps. Tech does recommend a compressor saver.
Tech started with the airhandler where tech found everything to be working properly tech did find that the drain line is starting to have build up tech moved to the condenser where tech found the inrush amps were high tech found everything else to be up to standards
Quoted a level 2 and 3 18k mini-split and a level 2 and 3 24k mini-split
Super tune up performed today on a carrier heat pump with air handler installed in 2020. All electrical connections are tight with no corrosion. Heat strips are pulling proper amperage. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Highly suggest adding a compressor saver to the outdoor unit to help with the efficiency and reliability of the system upon start up.
Blower motor failure - replaced with psc motor and added a relay, system is functional.
Customer states that the heat pump was not running on his dual fuel system and that only the propane furnace was running. Technician turned up the thermostat 2 degrees and the heat pump came on. Performed function check in heating and auxiliary heating. All systems are operating as they should. Helped customer set a program on his thermostat. Let system run for an hour to see if the problem would present itself. Problem that the customer stated did not occur. System running and heating the home upon departure.