Cody was knowledgeable and professional. He was able to quickly service my unit and replace the UV bulb.
Ian was able to quickly find the problem and get the compressor working again.
I would definitely recommend them! Quick and friendly service. I called them about 7:30 pm Sunday and they were here the very next day Monday @ 10 am to fix my AC. Ian Conrad is definitely great at his job, and very professional. Thank you to hum, and their company. If I could I would give them 10 stars
Cody was efficient and pleasant and Explained everything he did and everything he found …. Enjoyable
Ian was very professional and explained everything as he went. He diagnosed and cleaned my unit without Hard selling me on anything new. I really appreciate his honesty and work ethic.
Good explanations using visuals, pleasant , good demeanor - pleasure to have in my home
Mark’s attention to detail and thorough explanations provided peace of mind.
Tyler was professional, honest & respectful. Appreciate Corin promptly correcting the scheduling mistake the original service scheduler made with my appt..
Appreciate Justin being on time, courteous & knowledgeable! He was efficient & informative. Plan to reschedule him for installation of a compressor saver, appreciate not being pressured to make that decision today, I would NOT have considered or trusted his suggestion had I been pressured!
Arrived to no cool on smaller primary bedroom system. Goodman 2 ton heat pump installed in 2019. Resting pressures are at 22 psi. Performed leak search. Found leak in bottom side of evaporator coil. Suggest replacing the system due to the current system having no warranties. Comfort advisor is scheduled to meet with the customer in Monday afternoon.
We will replace 3 hose bibbs around home 6/3/25 wg Returned and replaced 3 threaded outside faucets around home. No leaks at this time. 1 yr warrant y
2020 2.5t attic horizontal hp foam insulation. System down upon arrival. Diagnostic discovered failed 35/5 dual run capacitor. Replaced. System cooling. Homeowner is moving within a year and declined membership benefits. System cooling upon departure with tstat set to 74° per homeowner. 88° ambient.
When technician arrived the AC downstairs was not working thermostat was blank. Technician went to attic and found plugged drain, found the drain lines run into masterbath sink so I removed that and found plugged line going into the sink so I cleared the plugged line re installed the flex hose and water drained through it. Technician got some bleach water from homeowner and flushed both attic systems. Then technician checked coils, blower wheel, temperature splits, refrigerant pressures including superheat and subcool, checked capacitors and contactor, and washed outdoor coil. 70/5 capacitor tested at 68.4 and 5 and contactor starting to pit will quote to customer. Homeowner asked for technician to install the new contactor and dual run capacitor so I replaced and tested. Unit is good to go
Customer only wanted estimate to replace 3 outside faucets. He declined tune up. No repairs done today
2016 3t Lennox hp attic horizontal. Homeowner was not home upon arrival, waited appropriately. Recieved permission from homeowner through dispatch to look at the condenser unit. System off upon arrival. Once homeowner arrived. I accessed the indoor unit and quickly found the SAFTEY drain switch had been activated on the secondary line. I cleared the drain blockage, monitored refrigerant system. Fully functional and cooling upon departure. I expressed concerns about maintenance but homeowner declined membership. Homeowner also claimed the system hasn't been on for a month. Homeowner purchased a drain clear.
Installed customer provided water softener flushed out entire fresh water system changed fill valve in guest toilet flush3d water heaters and changed out boiler drain on water heater
5/12/25 Customer said we where not supposed to be out until this evening they have an appointment they are going to will return later today
Upon arrival tech talked with home owner and started with the super time up tech Started with the air handler tech found that the system is running the way that is meant to tech did find that the system is starting to have biological growth grow in the system All electrical connections are tight and have no corrosion on them at this time Tech moved to the condenser where tech got a high inrush amo draw Tech washed and waxed the system Tech talked to home owner about findings
5/6/25 Customer would like to reschedule due to the rain. Customer would like to reschedule for next month.
Installed wwsp. Emailed estimates. New member. CUSTOMER WOULD LIKE TO HAVE AN HVAC TECH OUTTO DIGNOSE AC SYTEM NEXT WEEK MONDAY- WEDNESDAY. 5/5-5/7. PLEASE CONTACT CUSTOMER TO SCHEDULE APOINTMENT.
Super tune up performed today on a 5 year old Lennox straight electric system. 45/10 auxiliary motor start is showing as weak and is out of manufacture tolerance. This needs to be replaced. System does not have any drain protection. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Customer declined repairs at this time.
Replace frost free hydrant on back corner of home. Faucet broke in wall while removing. Was able to remove faucet without removing brick or drywall. Customer was not interested in membership at this time
Confirmed leak in the condenser coil. Because of the location of the leak replacement of condenser coil is highly suggested. Emailed estimate to the customer.
2024 Revolv Airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil has slight dust and biological growth build up 2024 Ducane Straight Cool Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Uv system, anti microbial pan treatment and compressor saver