Great job. Showed up and fixed the problem. Highly recommend
Justin is a great tech. Attention to detail and very knowledgeable.
Recently had our 2 A/C systems "serviced" for a nominal fee. The "service" was just electrical and temperature tests and arranging a sales appointment. Our clogged condensate drain was ignored. We were told we had a leak in the newest system and they scheduled someone to give us estimates. We paid Arthur Hagar A/C for a second opinion. They flushed the clogged condensate drain, installed a cleanout and showed us that the refrigerant was NOT leaking. They also showed us that the gauge readings matched the specs on the units.
Justin was very professional and fixed the issue very quickly
Hunter was great and took his time to identify the issue! I will be back -
I want Justin back if I need help again. Very courteous and helpful.
Came out right away....even on a Hot busy day in the air conditioning world and fixed my problem. Thanks again!
Tyler was personable, knowledgeable, and very informative. I gave him an A+.
We will install new gas valve on rinnai tankless water heater this part will need to be ordered
Found unit frozen solid and blower motor is burned out. Do to a faulty txv and leaks in evap coil. I recommend replacing system due to being 27 years old. Replaced blower motor and verified system started cooling.
Customer is going to buy disposal and we will return tomorrow to install last call
Replaced 3 switches and a dimmer. New member.
6/2025 home repair complete
9/1/25 Rescheduled for mark and tech tomorrow morning got customer draining but can't locate the issue do not know property
I have finished my electrical tune up, the panel looks good I I also found and tested the gfci's in the house
2021 Amana Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain has build up in the P trap Blower motor and wheel were acceptable Evaporator coil was acceptable UV lamp is out and passed replacement date Supply plenum has heavy biological growth build up 2021 Amana Heatpump Checked and tightened all electrical connections Dual Run cap was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended Compressor saver and UV system upgrade
Waiting to discuss with wife
Misunderstanding that led to diagnose of barn breaker direct short. c and water electric good.
Found no power. Sent to eletrical for main breaker tripping. When disconnect is turned off.
Wrote multiple water heater replacement options for customer. Customer will give us a call back just wanted me to email options to her at this time.
Upon arrival found drain was clogged and and float switch was tripping. Talked with previous tech and stated he notified them of drain issues. Cleared drain but was unable to get ahold of owners for repair or service fee. Pausing for now
Tech found that the system was completely frozen tech found that the ice was 5in we are going to have to run the system over night to see if there is a leak in the system Leak searched system. Found no leak but coil was completely clogged up did not have a filter in system. Used coil cleaner to clean coil best i could. Needs a pull and clean but not recommended on a 30 year old coil. Needs filter installed.