1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for weatherford, tx

Rated 4.9 out of 5 stars based on 822 customer reviews

Excellent service

Tyler was great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Inspection

Justin explained everything with lots of detail so I could understand the cleaning and repairs needed. He was outstanding!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A job well done in a timely manner

Justin completed the repair without any delays and described the failures of the applicable components. Job well done. Thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Justin was polite, kept me informed of what he was seeing and doing. Well trained, efficient, and got the job done like a professional. Thank You

  • Overall Experience
  • Quality
  • Price
  • Convenience

Hobson AC Service

Great job. Showed up and fixed the problem. Highly recommend

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Justin is a great tech. Attention to detail and very knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Not what it was decades ago

Recently had our 2 A/C systems "serviced" for a nominal fee. The "service" was just electrical and temperature tests and arranging a sales appointment. Our clogged condensate drain was ignored. We were told we had a leak in the newest system and they scheduled someone to give us estimates. We paid Arthur Hagar A/C for a second opinion. They flushed the clogged condensate drain, installed a cleanout and showed us that the refrigerant was NOT leaking. They also showed us that the gauge readings matched the specs on the units.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Justin was very professional and fixed the issue very quickly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Compressor replacement

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great knowledge and very courteous

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Hunter was great and took his time to identify the issue! I will be back -

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service

Very knowledgeable and polite service technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for weatherford, tx

Tyler L.

Tyler L. Job Checkin

Put up 3 boxes in the place of 3 disconnects under the house This needs to be revisited after consulting Brian


Tyler L.

Tyler L. Job Checkin

30 amp breaker has been replaced


Tyler L.

Tyler L. Job Checkin

Was not able to figure out the problem it does flash code but the fan inside of the controller was not functioning and I believe that it might be overheating I left the controller cover off and made sure that the fan inside of the controller was functioning before I left in the gentleman was told that if the pump shuts off again just reset the breaker until we can get back to it


Tyler L.

Tyler L. Job Checkin

Wasn't able to figure it out but we have reset the pump and it is working currently


Tyler L.

Tyler L. Job Checkin

First call tomorrow morning I'm changing this 30 amp breaker out


Mark W.

Mark W. Job Checkin

Checked voltage at disconnect and found one leg to be out. Water heater Set up appointment for electrician to come out this afternoon


Justin  P.

Justin P. Job Checkin

Performed Tune up on both systems today Found both indoor coils and blowers to have dust and dirt build up. Main system filter is not the correct size and is letting unfiltered air bypass. Checked all components on Heatpumps and and cleaned both outdoor units. Recommended blower cleanings, coil cleanings and compressor savers customer would like to talk with husband before making any decisions.


Mark D.

Mark D. Job Checkin

Arrived to a blockage in the primary drain. Cleared drain and added a drain pan treatment to ensure line stays clear. Performed function check. System running and cooling the home upon departure.


Justin  P.

Justin P. Job Checkin

2024 Goodman Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Blower motor and wheel were Evaporator coil was acceptable UV system is functional 2024 Goodman Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit


Justin  P.

Justin P. Job Checkin

2018 Goodman Airhandler Checked and tightened all electrical connections Drain was clear and draining at this time Drain has no drain safety Blower motor and wheel were acceptable Blower cap was within manufacture range Blower wires have biological growth build up Evaporator coil has Biological growth build up Supply plenum has dust, dirt and biological growth build up 2013 Frigidaire Heatpump Checked and tightened all electrical connections Disconnect is bypassed Dual Run cap is out of manufacture range Primary electrical unit has heavy pitting and carbon build up Refrigerant levels are off mainly due to poor airflow at Airhandler Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended replacement of dual run cap, disconnect and primary electrical unit. Recommended adding compressor saver, drain switch, UV 200 and level 2 duct


Justin  P.

Justin P. Job Checkin

Upon arrival indoor was blowing but outdoor was non functional. During evaluation found the dual run cap and compressor saver failed locking the system out. Replaced both and restarted system. Left with system cooling


Justin  P.

Justin P. Job Checkin

2022 Carrier Airhandler Checked and tightened all electrical connections Customer did not have filter to change today Drain was clear and draining at this time Blower motor and wheel were acceptable Evaporator coil was acceptable 2022 Carrier Heatpump Checked and tightened all electrical connections Dual Run cap was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from inside out Recommended UV systems to eliminate allergies and provid clean air in the house


Mark D.

Mark D. Job Checkin

9/9/25 Found compressor was grounded. Mega ohm it out and was bad Serial number 2103383728 Model number gSZ140481KF Replaced compressor and filter drier. Pulled vacuum to .500 microns and put back 10lbs of r410a refrigerant nperfomed function check. system running and cooling upon departure.


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Repaired one inch PVC water line tested for leaks no leaks job complete


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Looked at supposed water leak it was from clogged condensate drain that she had repaired by another company water has since dried up will bk if water reappears