The whole process was exceptional. My technician, Nathanael was super. He was prompt, polite and professional. He explained the problem with my A/C and resolved it. He also offered some options to improve the existing system. Could not be more impressed and satisfied.
Justin Pennington is a polite, personable young man. He answered our questions and quickly found the reason for the noise in our blower unit of the air conditioner. It only required a simple fix, and now it is much quieter.
I saw the price options for the task I was wanting. Water softener system. The only options provided were way, way to expensive for me. Thanked the technician. Technician was very cordial and polite.
Technician was very thorough and explained what he did and recommended service.
Mr Sheriff was 100% awesome very professional and corteous. We look forward to doing business with him again in the future.
Open start circuit code. Dual run cap had failed, replaced and reset system. Left system in cool mode
Found contactor not passing power. Replaced and checked pressures system is cooling properly
I have replaced the light fixture and I found nothing wrong with the garage door I tested it multiple times and it opens and closes fully Could not enter the house nor talk with customer so I can't do signatures
Wrote multiple options for customer on whole home filtration system. Customer will call us when ready
For this job I performed an inspection on the tankless water heater. Customer stated water flow is slightly restricted on the hot side. Recommendation is to have the heater flushed, this should help restore normal flow to the residence. Provided customer with an estimate to flush the heater, customer stated he wants to think about it.
Found capacitor was dead. Replaced and verified system was cooling customer declined lifetime way capacitor
Completed tune-up on a mini split and a heat pump the mini split is well within manufacture specs just believe a little bit undersized for garage area. Pressures are good and temperature split is good. On heat pump system everything is within manufacture specs if not just a little bit overcharged took some out and got it well within manufacturer specs has a turbo capacitor on it that is within manufacture specs indoor unit is full of biological growth definitely a recommend a blower cleaning and a coil cleaning and auv system so it does not come back after cleaning ductwork is older. Also on the condenser unit the line set goes underground in a loop and then comes up and into the building definitely recommend replacing that part of the line set when system goes out.
Emailed estimate to customer. She is getting other quotes. Plumbing Lead set and canceled unfortunately we did not see eye to eye on price.
2006 Lennox Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Drain has no drain safety Blower motor was acceptable Blower wheel has dust, dirt and biological growth build up Blower capacitor is weak rated at 20MFD TESTING 17MFD Evaporator coil has heavy rust build up with potential leaks Could not confirm leaks today. Airhandler has heavy biological growth build up 2006 Lennox Straight Cool Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit has heavy pitting and carbon build up on contacts Refrigerant levels were acceptable at this time Fan blades were acceptable Fan motor is louder than usual while running Compressor is nearing max run amps Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Recommended UV system for biological, le
Upon arrival tech found that the tvx was bad technician is ordering TXV technician is pausing job until part comes in
Replaced condenser coil, changed out 45/7.5 dual run capacitor and added a whole home surge protector in the main panel. Pulled vacuum to 500 microns and released the recovered refrigerant. Performed function check. System running and cooling the home upon departure.
Pricing on this estimate is to install a new Ingnitor on the existing water heater. While performing diagnostics on the unit, I checked the sight glass and looked for the spark. The Ingnitor has gone out, no spark while trying to ignite the pilot light. 7-17-25 After installing the new igniter, I noticed water was dripping down the side of the unit. I did a bit more investigatint to locate the source. Water is seeping through the seem of the water heater shell, this is a very good indication that there is a crack on the interior wall of the unit. The entire unit needs to be replaced
Tankless estimate. 199,000 BTU propane navien water heater. Propane line is above unit in attic. We will also trace cold line to washer and see if it is ran from soft water side. They are smelling sulphur when cold water only is ran in washer. Mr. Mason would like to talk to his wife about this. Need to set a follow up phone call for Monday after noon please
Need to order zone control board with a 12" damper and motor and a 14" damper and motor. Customer states that the bedrooms and the guest room are warm due to the zone system not working correctly. During renovations the contractor removed the zone sensors from the wall. Customer wants to install a new zone control system with thermostats in the rooms instead of the zone sensors. Requesting help from Brian H when parts come in.
Install 24k hp hz with high efficiency filtration, code kit and seal attic