1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for weatherford, tx

Rated 4.9 out of 5 stars based on 839 customer reviews

Excellent service

Justin was awesome. He explained everything that he was going to do and gave a summary of what he found.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service.

Don is awesome. Helpful professional info and opinions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledgeable !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job

Great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Efficient and Friendly Service

Mark fixed a problem with the HVAC quickly and effectively. I appreciate his friendly attitude and respect.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service Above and Beyond

Really good advice. He came up with other options that solved some HVAC issues. He came back later on his own time to give my special needs son some rodeo advice.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thorough Analysis

Justin did a thorough analysis of components and gave helpful recommendations.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Mark is a great technician! Truly appreciate his conversations, honesty and service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Mark was very knowledgeable, polite and helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Pushy Service

Very nice guy but a bit pushy on which unit we should purchase. We made our choice and he kept pushing us to go with a higher unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service As Always

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Professional, friendly, thorough!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for weatherford, tx

Justin  P.

Justin P. Job Checkin

Wired O to W on accident so system would constantly have the heatstrips running. Rewired Tstat wire and left with system in heat Callback on me


Justin  P.

Justin P. Job Checkin

Performed Tune up on system checked all functions of the Airhandler and found no issues performance wise. UV lamp was out and is passed replacement date Checked all functions of the heat pump and found the dual run cap was extremely weak on herm side. Replaced under P&L. Unable to wash the condenser coils at this time due to the home owner shutting off the outside water for winter time. Talked with customer about it and he did not want to turn the water on at this time. Installed UV 200


Mark D.

Mark D. Job Checkin

Heating tune up performed on a five year old Amana heat pump with air handler. Arrived to a failed 50/5 dual run capacitor that was preventing the outdoor unit from turning on. Replaced capacitor under warranty and performed function check. All electrical connections are tight with no corrosion. Filter is dirty and needs to be changed. Customer is aware and will change it when the new filter comes in. Refrigerant levels are in range. Reversing valve and defrost control board are working properly. Heat strips are pulling proper amperage.


Mark D.

Mark D. Job Checkin

Heating tune up perfomed today on a two year old Goodman heat pump. All electrical connections are tight with no corrosion. X13 blower motor is acceptable. Blower wheel and evaporator coil are acceptable. Refrigerant levels are in range. Heat strips are pulling proper amperage. Reversing valve and defrost control board are working as they should.


Justin  P.

Justin P. Job Checkin

2020 Goodman Airhandler Checked and tightened all electrical connections Filter was acceptable at this time Drain was clear and draining at this time Heat strips are functional and within manufacture range Blower motor and wheel were acceptable Blower cap was within manufacture range Evaporator coil was acceptable 2020 Goodman Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Compressor saver was functional Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the inside out Washed condenser coils from the inside out Recommended UV system for allergies and clean air


Justin  P.

Justin P. Job Checkin

Found w wire shorted from Tstat to Airhandler and primary electrical unit making very loud buzzing sound. Relocated thermostat and replaced primary electrical unit. Left with unit in heat


Mark W.

Mark W. Job Checkin

Gathered parts for job name Susan Holloway with Mark w


Don S.

Don S. Job Checkin

Ivvjvivi


Justin  P.

Justin P. Job Checkin

2016 Intertherm Airhandler Checked and tightened all electrical connections Changed customer provided filters Drain was clear and draining at this time Heat strips are functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable 2016 Coleman Heatpump Checked and tightened all electrical connections Refrigerant levels were acceptable at this time Dual run cap was weak, replaced under P&L Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended compressor to reduce compressor inrush amps


Justin  P.

Justin P. Job Checkin

Upon arrival system was set to 65 and thermostat was showing 63 and heating. Heatpump was not running and neither were the heatstrips, fan was running constantly. Pulled thermostat off the wall and jumpered the Heatpump, Heatpump ran in heat also jumpered the heatstrips and they ran as should. Nest thermostat has failed customer will replace it themselves NO CALLBACK


Justin  P.

Justin P. Job Checkin

2018 Trane Airhandler Checked and tightened all electrical connections Customer did not have extra filter tody Heatstrips were functional and within manufacture range Drain is clear and draining at this time Drain safety is present but was not wired into low voltage Blower motor and wheel were acceptable Blower housing and wires have heavy biological growth build up Evaporator coil was acceptable 2018 Trane Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Defrost board was acceptable Defrosted is functional at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended UV system to kill biological growth and promote clean air and compressor saver


Justin  P.

Justin P. Job Checkin

11/29/25 During tune up heavy rain started and became unable to perform tune up on outdoor. NEED TO RESCHEDULE FOR NEXT FRIDAY FIRST CALL TO FINISH OUTDOOR UNIT 12/5/25 9AM


Justin  P.

Justin P. Job Checkin

Thermostat was in properly programmed. Reprogrammed thermostat and wired system to legacy low voltage. Left with system heating Callback on install


Alex  D.

Alex D. Job Checkin

Level 4 42k h/p whole house surge protection


Justin  P.

Justin P. Job Checkin

Ambient temperature was acceptable to run the heatpump today. Heatpump is still going out on high head pressure, moved TXV bulb and ran system for ten minutes. TXV is not working properly talked with customer about replacement TXV. Customer stated they will talk with homeowner arlo about the situation and will be in contact with us