Excellent Service!

Justin was excellent and worked fast to fix our problem! Definitely would recommend to anyone!

  • Overall Experience
  • Quality
  • Price
  • Convenience

EXCELLENT

Professional and courteous! He quickly diagnosed the problem and had it fixed within the hour. He came after hours with a smile on his face.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick response

Good attitude, friendly, and very knowledgeable on our system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job well done

Professional an explained the situation. Very knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Kellen was professional, friendly and very informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great!

Awesome job! Very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific Service!

Ian is the best ! Thanks so much for taking care of us.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellant Service

Smart, trustworthy Technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic service

Mark and the gentleman with him were very pleasant and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional

It was for a quote on mini split replacement

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service Yhey know their business

Two hard working knowledgeable young men Your company was well represented Good job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for weatherford, tx

Mark W.

Mark W. Job Checkin

Make estimate


Mark W.

Mark W. Job Checkin

Will need to get him a estimate on walkin unit 6×12 is the size of room Also need a txv for unit we put in put in. Hunter is going to pick it up


Lisa M.

Lisa M. Job Checkin

Kellen M. completed annual air conditioning tuneup,


Lisa M.

Lisa M. Job Checkin


Kellen M.

Kellen M. Job Checkin

3 ton carrier straight electric attic horizontal 2015 Condenser fan motor fail. Dual run capacitor fail. Compressor amping above manufacturers data. Leaks detected in coil. Heavy biological growth indoor unit. Weak filtration. No warranty. System down upon arrival. Homeowner states Compressor has been sounding odd lately. After diagnostic, I dove deeper and performed a courtesy leak detection and found a leak of refrigerant. Homeowners have a newborn coming into the home soon and are very concerned about the IAQ. Asked about duct cleaning because of it (before they knew what I found in the indoor unit). I explained the benefits of IAQ products including upgrade filter system. After explaining that the systems performance is severely lacking and it has no manufacturers warranty to off set the cost of repairs they agreed to have a CA appointment 6/17/24 @3p to discuss a more efficient system. Both homeowners are first responders so please price accordingly. Tech recommended solut


Kellen M.

Kellen M. Job Checkin

Tiny home village. Ductless multi head mini split. Manufacturer warranty expired. Washed condenser unit coil. Washed both indoor head filters. System is fully functional. Homeowner has a home warranty. Declined membership due to home warranty.


Justin  P.

Justin P. Job Checkin

Customer stated they replaced tstat, and system would blow hot air in cool mode. Customer also stated that the lineset was hot as well. After evaluation found thermostat was programed to energize in heat mode cause the system to heat in cool mode and cool in heat mode


Tyler S.

Tyler S. Job Checkin

06/15/24 TS- toilet needs to be replaced. Has a weak flow due to calcium buildup to a degree that just needs to be replaced instead. Waterheater is new 2020 a few water line joints have galvanized pipe and need to be replaced. Customer declined any fixes at this time


Cody B.

Cody B. Job Checkin

Tech Cody arrived to customer's home and met the homeowners. The indoor would come on but not the outdoor. Outside the board was giving the locked rotor fault code, I diagnosed a failed compressor saver. The unit had Warranty P&L so I replaced the part and then the unit turned on and started cooling.


Justin  P.

Justin P. Job Checkin

2012 intertherm airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Blower motor and wheel were heavily compacted with dust Blower auxiliary motor starter was weak Evaporator coil was heavily compacted with dust and biological growth 2012 straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Blower and Evaporator cleaning, auxiliary motor starter for Blower motor and compressor saver for longevity of compressor


Cody B.

Cody B. Job Checkin

Tech Cody arrived to customer's home and met the homeowners. Indoors the filter was replaced, the coil is clean, the blower wheel blades were clean but the blower case had biological growth on it. The heat strips were functioning in range. I noticed that the primary and secondary drain lines were clogged and water had completely filled the drain pan and was starting to leak out of the unit into the emergency drain pan. Outside I hooked up my guages and found the refrigerant circuit to be good, the compressor and fan motor were operating within manufacturer range. The capacitor and primary electrical control were both in good condition. I washed and waxed the unit at the end. I shared my findings with the homeowners and Gabe them all their options for maintaining the unit and preventing further issues. They decided to talk it over first before making any decisions.


Mark D.

Mark D. Job Checkin

Arrived to no cool. Found the 4 year old goodman straight electric system to be low on r410a refrigerant. Performed leak search and found a leak in the evaporator coil. System is under a parts only warranty. Customer asked if I could check the refrigerant on the 2007 carrier r22 system next to the system I was diagnosing. Found the r22 system to be low on refrigerant as well. Delta T is 11 degrees and superheat is 45 degrees. Vapor line temp is 72 degrees and vapor saturation temp is 28 degrees. Suggest replacement on the older r22 system. As well as evaporator coil replacement on the 2020 Goodman air handler.


Mark D.

Mark D. Job Checkin

Changed out air filter and installed customer supplied UV bulb. System running in cool upon departure.


Cody B.

Cody B. Job Checkin

Tech Cody arrived to customer's home and met the homeowner. I started the tune up upstairs, the was clogged so I replaced, the coil was mostly clean but had some dust buildup. The blower was clean, there was some biological growth starting to appear on the motor wires. The heat strips were operating within manufacturer range. The temperature split was only 9 degrees and when I hooked up my guages the subcoolmwas at 1 degree, I did a courtesy leak search but was unable to pinpoint all the leaks. Outside I found the capacitor to be weakened and considered failed by the manufacturer, the compressor and fan motor were operating within manufacturer range. I washed the coil outside before waxing the unit. Imshared my findings with the homeowner and recommended they charge the system up with refrigerant, as well as replace the weak capacitor and install a compressor saver to help lower stress on the compressor.


Tyler L.

Tyler L. Job Checkin

I replaced her dryer plug with a 3 prong