Technician was very nice, helpful and very knowledgeable. The UVC system price is a little high.
he did a great job and if I could give him 10 and I gave him to him for the job have a good day
Daniel was very helpful in getting the AC system on line in our new house,
Jerred came out and saved the day for us on a Sunday and he was very thorough in explaining everything that needed to be done and how we could keep our problem from happening again.
Tyler was super helpful and solution oriented. I would love to work with Tyler again!
I have not read his report yet, but when he was here, the way he talk, the way he acted was in a professional manner. He did everything right, I just didn’t have the money to say go ahead and do it today.
Installed secondary drain pan, 2x safety switches, 2x drain line repairs and supported the drain line to the master bedroom.
He came to job for breaker tripping and replaced breaker with new one
Put the Wi-Fi password into the thermostat system now heating
Emailed estimates for service repair and exterior light repair.
Outside conduit circuit extension. Emailed estimate to customer. Also repair 2 sets of 3 way switches. Circuit 23
Arrive don’t performed the plumbing inspection and made some recommendations to customer. He had someone there working on his house at the time. Said he will call when he is ready to perform the plumbing repairs.
Today I showed up for a membership heating tune-up for two one year old heat pump units but it turned into an evaluation of one and a tune-up on the other because upon arrival the downstairs unit was a solid block of ice I got it thawed out while I was running the tune-up on the upstairs unit and put it back into heat mode and let it run Cycles everything was functioning as it should turns out we need to install a heat pump gutter at the roof line directly above the downstairs unit this unit also needs to replace the value germicidal light bulb as it has been over a year now as far as the upstairs unit the run capacitor was almost out of range and the start capacitor was no longer doing its job this unit also needs the value germicidal light bulb replaced there was some discrepancies regarding the coverage of their membership and warranty however we got everything straight and clear they are now signed up for the new home budget and protection plan with a five-star lifetime labor warra
Located leak on drain pan sold new drain pan and float switch pan that is current is 36×36 will need 2 float switches Set to order pan and float switch for Justin to install when it arrives Left estimates for tankless system and flood stop Also set lead set for electrician
I was here because there is water spot above the kitchen so I went up and poured two gallons of water down the drain line and could not find a leak in his drain or find any damage that could have caused the water spot customer stated it probably showed up about a month ago and so customer wanted a plumber to come out and check where it’s coming from. They want to be called for scheduling
Super tune up on 2 2012 amana gas systems down stairs furnace blower capacitor is low and ignition components are showing carbon build up. Upstairs system ignition components also showing wear. Recommend replacing ignition components for reliable heating.condenser fan motor has some discoloration due to heatl
Super tune up on 2012 amana gas system ignition components showing signs of carbon build up most common failure on a gas furnace. Land lord would like to hold off on any repairs at this time. Changed filter provided by customer.
Arrived for Super tune up Washed condensor and tightened connections Filter was clean Delta 17 All cooling and heating components are in tolerance Reccomendation of compressor saver kit to lower Inrush LRA on start up System left on heat at exit
Arrived for STU filter fine Drains clear Furnace components in spec Small amount of rust on the heat exchange Blower and coil dusty Installed IAQ200 due to biological growth in the plenum Condenser coil clean Motors and capacitors fine Hard start kit recommended due to compressor exceeding LRA at start up